ID:18018 CASCADE primitive "<name>" contains fan-out to more than one destination
CAUSE: The specified
CASCADE
primitive contains fan-out to multiple destinations. However, CASCADE
primitives should contain fan-out to a single destination.
ACTION: Modify the design so the fan-out is on the input side of the CASCADE
primitive, so the primitive contains fan-out to a single destination.