ID:12146 DQS I/O pin "<name>" has conflicting DQS input reference clock assignment
CAUSE: The specified DQS I/O pin is referenced by a different system clock than the system clock that is connected by the altdqs
megafunction. The DQS I/O pin can be referenced only by one system clock.
ACTION: Delete the
DQS Input Reference Clock
logic option on the DQS I/O pin. In general, the
DQS Phase Shift
,
DQS Frequency
, and
DQS Input Reference Clock
logic options are ignored if you use the altdqs
megafunction.