ID:15913 Input port <text> of PLL "<name>" must be connected to the <text> output of the same PLL.
CAUSE: When the OPERATION_MODE
parameter of the specified PLL is set to NO_COMPENSATION
, the fbin
input of the specified PLL must be connected to the fbout
output of the same PLL.
ACTION: Make sure the fbin
input and the fbout
output of the specified PLL are connected properly.