ID:21005 The dataout output of output phase alignment primitive "<name>" must drive oe input of an I/O output buffer (directly or indirectly through up to 2 delay chain primitives) when OPERATION_MODE parameter is set to "oe" or "extended_oe"
CAUSE: The dataout
output of the specified output phase alignment primitive has an illegal connection.
ACTION: Check the design and make sure that the specified dataout
output is driving the oe
input of an I/O output buffer. You can also connect the dataout
output to the oe
input indirectly through up to two delay chain primitives. In this configuration, the dataout
output of the specified output phase alignment primitive would drive the datain
input of a delay chain primitive and the dataout
output of the same delay chain primitive would drive the oe
input of an I/O output buffer. Alternatively, you can change the value of the OPERATION_MODE
parameter.