ID:15391 DSP block output WYSIWYG primitive "<name>" has an ACC_ADDER_OPERATION value set to SUBTRACT, but OPERATION_MODE of DSP block output WYSIWYG primitive "<name>" is set to a value other than ACCUMULATOR or ACCUMULATOR_CHAIN_OUT
CAUSE: The specified DSP block output WYSIWYG primitive has an ACC_ADDER_OPERATION
value set to SUBTRACT
, but the OPERATION_MODE
parameter is set to a value other than ACCUMULATOR
or ACCUMULATOR_CHAIN_OUT
. The specified DSP block output WYSIWYG primitive must have the OPERATION_MODE
parameter set to ACCUMULATOR
or ACCUMULATOR_CHAIN_OUT
.
ACTION: Set the OPERATION_MODE
of the specified WYSIWYG DSP block output primitive to ACCUMULATOR
or ACCUMULATOR_CHAIN_OUT
, or set the ACC_ADDER_OPERATION
value of the specified WYSIWYG DSP block output primitive to ADD
.