ID:15371 WYSIWYG DSP block multiplier primitives "<name>" and "<name>" are connected to ports <name> and <name> of the same DSP block output WYSIWYG primitive "<name>", but round ports are not connected to the same signal source
CAUSE: The specified WYSIWYG DSP block multiplier primitives are connected to the specified datain
ports of the specified DSP block output WYSIWYG primitive, but the round
ports are not connected to the same signal source. When DSP block multiplier WYSIWYG primitives are connected to the datain
ports of a DSP block output WYSIWYG primitive, the round
ports must connect to the same signal source.
ACTION: Connect the round
ports of the specified DSP block multiplier WYSIWYG primitives to the same signal source.