Auto Open-Drain Pins logic option
A logic option that directs the Compiler to automatically convert a tri-state buffer with a strong low data input into the equivalent open-drain buffer, as illustrated in the following code example:
IF (EN = '0') THEN
OD_Pin <= 'Z';
ELSE
OD_Pin <= '0';
END IF;
This option cannot be used with netlists that are synthesized with third-party synthesis tools. To use this option, you must turn on the Perform WYSIWYG Primitive Resynthesis logic option.
This option must be assigned to a design entity or it is
ignored. This option can be used in conjunction with the Weak
Pull-Up Resistor option to pull the bus to VCC
.
This option is available for all Intel devices supported by the
Quartus® Prime software.