ID:328025 Enable Bus-Hold Circuitry and Passive Resistor logic options are specified for instance "<name>". Only Enable Bus-Hold Circuitry will be used for this instance.

CAUSE: You turned on Enable Bus-Hold Circuitry and Passive Resistor logic options for the same specified instance name. However, the Enable Bus-Hold Circuitry and Passive Resistor logic options cannot both be on at the same time for the same instance. When this condition occurs, the Quartus Prime software uses the Enable Bus-Hold Circuitry logic option.

ACTION: If you want to allow the Quartus Prime software to ignore the Passive Resistor logic option, no action is required. If you want to use the Passive Resistor logic option, edit the logic option settings to make sure Enable Bus-Hold Circuitry and Passive Resistor are not on at the same time for the same instance.