CAUSE: You added the specified signal to the signal set and defined it as an input for triggering, but the specified trigger does not use the signal in its advanced trigger conditions. Every signal in the signal set that is defined as an input for triggering should be used in the trigger's advanced trigger condition.
ACTION: If you do not want to use the signal in the trigger's advanced trigger conditions, turn off the signal's trigger enable. Otherwise, make sure the signal is used in the trigger's advanced trigger conditions.