ID:186350 Clocks of a group of DQS I/O pins and their DQ I/O pins are driven by different PLLs

CAUSE: The clocks of a group of DQS I/O pins and their corresponding DQ I/O pins are driven by different PLLs. This is legal, but for best results, all clocks should be driven by the same PLL.

ACTION: No action required. To avoid receiving this message in the future, modify the design so the same PLL drives all clocks in the group.