CAUSE: All the data inputs of the specified SERDES transmitter must be synchronized to the core clock. However, only some of the data inputs of the specified SERDES transmitter are synchronized to the core clock.
ACTION: Modify the design to synchronize all data inputs of the SERDES transmitter to the core clock.