ID:171044 Removed node "<name>" from LogicLock region "<name>" -- node is used to drive an internal global signal

CAUSE: You assigned the specified node to the specified LogicLock region. However, because the node is used as to drive an internal global signal, the Fitter removed the LogicLock region assignment for the node. Nodes used to drive internal global signals cannot have LogicLock region assignments.

ACTION: If you require the node to be assigned to the specified location, assign the node to a custom region. To avoid receiving this message in the future, turn on the Prevent Assignment to LogicLock Regions logic option for the specified node.