ID:169184 Following <number> pins use on-chip clamping diodes but the I/O bank VCCIO is not <name>.

CAUSE: Your design has specified I/O pins with on-chip clamping diodes turned on in I/O banks when VCCIO is not 3.3V. Altera does not support this application since the clamping diode is intended for use with 3.3V VCCIO. IBIS models for this implementation will not be made available.