ID:186111 Can't place GXB receiver channel "<name>", a logical channel <number> in XAUI synchronization mode, at location <name>, a physical channel <number> in quad

CAUSE: You assigned the specified gigabit transceiver block (GXB) receiver channel to the specified location. However, the Fitter cannot place the GXB receiver channel at the specified location because the physical location does not correspond to the logical location of the channel in XAUI synchronization mode.

ACTION: Assign the GXB receiver channel to a legal location or delete the location assignment.