ID:13147 Input clock of DDIO node "<name>" associated with DQS/DQ/DM pin is not driven by PHY Clock Buffer.

CAUSE: Input clock of a DDIO node associated with DQS/DQ/DM pin is not driven by PHY Clock Buffer.

ACTION: Modify the design so that the input clock of the DDIO node is connected to a PHY Clock Buffer.