List of Messages |
CAUSE: The specified DQS_DELAY_CHAIN is driving the clk and/or clk_n ports of several DDIO_IN primitives. Each DDIO_IN primitive that the DQS delay chain drives must have the same use_clkn WYSIWYG parameter value; however, the Quartus Prime software detects different values.
ACTION: Modify the parameter values for some primitives, or modify the connection of your design. For more information about the configuration of the use_clkn parameter, refer to the submessages.