ddr_T_main_Probe_Filters_0_Opcode

         
	Packet Probe register Opcode is a 4-bit register that selects candidate packets based on packet opcodes (0 disables the filter):
	
      
Module Instance Base Address Register Address
soc_ddr_scheduler_inst_0_ddr_T_main_Probe 0xF8000000 0xF8000060

Size: 32

Offset: 0x60

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

URGEN

RW 0x0

LOCKEN

RW 0x0

WREN

RW 0x0

RDEN

RW 0x0

ddr_T_main_Probe_Filters_0_Opcode Fields

Bit Name Description Access Reset
3 URGEN
Selects URG packets (urgency).
RW 0x0
2 LOCKEN
Selects RDX-WR, RDL, WRC and Linked sequence.
RW 0x0
1 WREN
Selects WR packets.
RW 0x0
0 RDEN
Selects RD packets.
RW 0x0