Probe_MPU_main_Probe_StatAlarmMax

         
      
Module Instance Base Address Register Address
i_noc_mpu_m0_Probe_MPU_main_Probe 0xFFD15000 0xFFD15030

Offset: 0x30

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

STATALARMMAX

RW 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

STATALARMMAX

RW 0x0

Probe_MPU_main_Probe_StatAlarmMax Fields

Bit Name Description Access Reset
31:0 STATALARMMAX
Register StatAlarmMax contains the maximum count value used in statistics alarm comparisons.The number of bits is equal to twice the value set for parameter wStatisticsCounter. When parameter statisticsCounterAlarm is set to False, StatAlarmMax is reserved.
RW 0x0