Probe_emacs_main_Probe_StatAlarmStatus

         
      
Module Instance Base Address Register Address
i_noc_mpu_m0_Probe_emacs_main_Probe 0xFFD14400 0xFFD14434

Offset: 0x34

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

STATALARMSTATUS

RO 0x0

Probe_emacs_main_Probe_StatAlarmStatus Fields

Bit Name Description Access Reset
0 STATALARMSTATUS
Register StatAlarmStatus is a read-only 1-bit register indicating that at least one statistics counter has exceeded the programmed values for registers StatAlarmMin or StatAlarmMax. Output signal StatAlarm is equal to the values stored in register MainCtl fields StatAlarmStatus and AlarmEn. When parameter statisticsCounterAlarm is set to False, StatAlarmStatus is reserved.
RO 0x0