ERRINTENS
Error Interrupt set
| Module Instance | Base Address | Register Address |
|---|---|---|
| ecc_hmc_ocp_slv_block | 0xFFCFB000 | 0xFFCFB114 |
Offset: 0x114
Access: RW
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
| Bit Fields | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved |
HMI_INTRS 0x0 |
DERRINTS 0x0 |
SERRINTS 0x0 |
||||||||||||
ERRINTENS Fields
| Bit | Name | Description | Access | Reset |
|---|---|---|---|---|
| 2 | HMI_INTRS | This bit is used to set the general purposes HMI interrupt error. 1'b0: writing of zero has no effect 1'b1: writing one, HMI_INTREN bit to 1. This is performing a bitwise writing of this feature. |
RW | 0x0 |
| 1 | DERRINTS | This bit is used to set the double-bit error interrupt bit. Reads reflect DERRINTEN. 1'b0: writing of zero has no effect 1'b1: writing one, DERRINTEN bit to 1. This is performing a bitwise writing of this feature. |
RW | 0x0 |
| 0 | SERRINTS | This bit is used to set the single-bit error interrupt bit. Reads reflect SERRINTEN. 1'b0: writing of zero has no effect 1'b1: writing one, this bit will set SERRINTEN bit to 1. This is performing a bitwise writing of this feature. |
RW | 0x0 |