ERRINTENR

         Error Interrupt reset.
      
Module Instance Base Address Register Address
ecc_otg0_ecc_registerBlock 0xFF8C8800 0xFF8C8818
ecc_otg1_ecc_registerBlock 0xFF8C8C00 0xFF8C8C18

Offset: 0x18

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

SERRINTR

0x0

ERRINTENR Fields

Bit Name Description Access Reset
0 SERRINTR
This bit is used to reset the single-bit error interrupt bit. Reads reflect SERRINTEN.
1’b0: Writing of zero has no effect.
1’b1: By writing one, this bit will reset SERRINTEN bit to 0. This is performing a bitwise writing of this feature.
RW 0x0