SERRLKUPA0

         Single-bit error address in LOOKUP TABLE for PORTA.
      
Module Instance Base Address Register Address
ecc_nandw_ecc_registerBlock 0xFF8C2800 0xFF8C2890

Offset: 0x90

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

VALID

RW 0x0

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

Address

RO 0x0

SERRLKUPA0 Fields

Bit Name Description Access Reset
31 VALID
Valid flag bit. Valid bit indicates if the address in this register is current or stale.
RW 0x0
6:0 Address
Recent Single-bit error address. 
This register shows the address of the each single-bit error. RAM size will determine the maximum number of address bits. If ram size is 32 Kbytes, bit 30-16 will be reserved and read as zero.
RO 0x0