ECC_Addrbus

         MSB bit of address is determined by ADR.
      
Module Instance Base Address Register Address
ecc_emac0_rx_ecc_registerBlock 0xFF8C0800 0xFF8C0840
ecc_emac1_rx_ecc_registerBlock 0xFF8C1000 0xFF8C1040
ecc_emac2_rx_ecc_registerBlock 0xFF8C1800 0xFF8C1840

Offset: 0x40

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

ECC_AddrBUS

0x0

ECC_Addrbus Fields

Bit Name Description Access Reset
11:0 ECC_AddrBUS
Address will be driven to RAM to either read or write the data. Address will be latched by the RAM when the Enbus is asserted.
RW 0x0