di_inject1

         Register provided to control the error injection feature.
      
Module Instance Base Address Register Address
i_nand__reg_apb__10b80000__rf_di_regs__SEG_L4_MP_nand_s_0x0_0x10000 0x10B80700 0x10B80708

Size: 32

Offset: 0x8

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved_5

RO 0x0

di_inj_reg_value

RW 0x0

Reserved_4

RO 0x0

di_inj_data_rd_addr

RW 0x0

di_inj_data_wr_addr

RW 0x0

di_inj_data_wr_crc

RW 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved_1

RO 0x0

di_inj_data_rd_par

RW 0x0

di_inject1 Fields

Bit Name Description Access Reset
31:24 Reserved_5
Reserved bitfield added by Magillem
RO 0x0
23:20 di_inj_reg_value
Inject error for register read value.
RW 0x0
19 Reserved_4
Reserved bitfield added by Magillem
RO 0x0
18 di_inj_data_rd_addr
Inject error on address for read data.
RW 0x0
17 di_inj_data_wr_addr
Inject error on address for write data.
RW 0x0
16 di_inj_data_wr_crc
Inject CRC error for write data path.
RW 0x0
15:8 Reserved_1
Reserved bitfield added by Magillem
RO 0x0
7:0 di_inj_data_rd_par
Inject parity error for read data path.
RW 0x0