WDT_CCVR

         Current Counter Value Register.
      
Module Instance Base Address Register Address
i_watchdog_2__watchdog_csr__10d00400__wdt_address_block__SEG_L4_SYS1_wd2_0x0_0x100 0x10D00400 0x10D00408

Size: 32

Offset: 0x8

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

wdt_ccvr

RO 0x7FFFFFFF

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

wdt_ccvr

RO 0x7FFFFFFF

WDT_CCVR Fields

Bit Name Description Access Reset
31:0 wdt_ccvr
This register, when read, is the current value of the internal
counter. This value is read coherently when ever it is read,
which is relevant when the APB_DATA_WIDTH is less than the
counter width.
RO 0x7FFFFFFF