TFL

         Transmit FIFO Level.
This register is valid only when the DW_apb_uart is configured to have additional FIFO status registers
implemented (FIFO_STAT = YES). If status registers are not implemented, this register does not exist and
reading from this register address returns 0.
      
Module Instance Base Address Register Address
i_uart_0_uart_address_block 0xFFC02000 0xFFC02080
i_uart_1_uart_address_block 0xFFC02100 0xFFC02180

Size: 32

Offset: 0x80

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

RSVD_TFL_31toADDR_WIDTH

RO 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

RSVD_TFL_31toADDR_WIDTH

RO 0x0

tfl

RO 0x0

TFL Fields

Bit Name Description Access Reset
31:8 RSVD_TFL_31toADDR_WIDTH
Reserved bits: 31 downto addr bus width + 1 - Read Only
RO 0x0
7:0 tfl
Transmit FIFO Level.
This is indicates the number of data entries in the transmit FIFO.