1. Intel Stratix 10 Clocking and PLL Overview
1.1. Clock Networks Overview
Intel® Stratix® 10 devices contain dedicated resources for distributing signals throughout the fabric with balanced delay. These resources are typically used for clock signals and other signals with low-skew requirements. In Intel® Stratix® 10 devices, these resources are implemented as a programmable clock routing network, which allows for the implementation of low-skew clock trees of various size.
1.2. PLLs Overview
Phase-locked loops (PLLs) provide robust clock management and synthesis for device clock management, external system clock management, and high-speed I/O interfaces.
The Intel® Stratix® 10 device family contains the following PLLs for core applications:
- fPLLs—can function as fractional PLLs or integer PLLs
- I/O PLLs—can only function as integer PLLs
The fPLLs are located adjacent to the transceiver blocks in the transceiver banks. Each transceiver bank contains two fPLLs. You can configure each fPLL independently in either conventional integer mode, or fractional mode. In fractional mode, the fPLL can operate with third-order delta-sigma modulation. You can configure each fPLL to generate either a transmitter (TX) clock for a transceiver or to provide a single clock to the core.
The I/O PLLs are located adjacent to the hard memory controllers and LVDS serializer/deserializer (SERDES) blocks in the I/O banks. Each I/O bank contains one I/O PLL. The I/O PLLs can operate in conventional integer mode. Each I/O PLL has nine C counter outputs.
Intel® Stratix® 10 devices have up to 48 fPLLs and 42 I/O PLLs in the largest densities devices.
2. Intel Stratix 10 Clocking and PLL Architecture and Features
2.1. Clock Networks Architecture and Features
2.1.1. Clock Network Architecture
Each Intel® Stratix® 10 device is divided into a number of evenly sized clock sectors.
2.1.1.1. Clock Network Hierarchy
The Intel® Stratix® 10 clock network is organized in a hierarchy with 3 levels.
2.1.1.2. Clock Sector
Each clock sector has dedicated sector clock (SCLK) and row clock network resources that can be accessed by the programmable clock network. Each clock sector is also surrounded by programmable clock network resources. On each side, there is a channel that contains 32 independent bidirectional clock wires. At each corner, there is a set of programmable clock switch multiplexers which can route between these clocks wires.
A signal on a vertical clock wire can enter the sector to its left or right via clock tap multiplexers. The clock tap multiplexer drives a sector clock, which distributes the signal to each row in the clock sector. In each row, there are six row clock resources which connect to all core functional blocks, PLLs, and I/O interfaces in the sector, and to adjacent transceivers.
2.1.1.3. Programmable Clock Routing
The Intel® Quartus® Prime software automatically configures the clock switch, clock tap, SCLK, and row clock multiplexers to generate skew-balanced clock trees. The resulting routing path distributes the signal from the clock source to all target destinations in one or more clock sectors.
The Intel® Quartus® Prime software creates efficiently balanced clock trees of various sizes, ranging from a single clock sector to the entire device, as shown in the following figure. By default, the Intel® Quartus® Prime Software automatically determines the size and location of the clock tree. Alternatively, you can directly constrain the clock tree size and location either with a Clock Region assignment or by Logic Lock Regions.
The total insertion delay for the clock network depends on the number of clock resources needed to implement the clock tree, increasing with the number of clock sectors reached and the distance of the furthest clock destination from the signal source. As delay increases, the worst-case skew for crossing clock sectors using different clock tree branches grows, potentially degrading the maximum performance. For very high-speed clock signals, it is advantageous to reduce the number of clock sectors driven, which reduces the clock skew, and to reduce the distance between the clock source and the furthest destination, which reduces both clock skew and total clock insertion delay.
2.1.2. Clock Resources
Device | Number of Resources Available | Source of Clock Resource |
---|---|---|
|
Transceiver: 9 differential I/O: 32 single-ended or 16 differential |
For Transceiver pins: REFCLK_GXB[L,R][1,4][C,D,E,F,G,H,I,J,K,L,M,N]_CH[B,T][p,n] For I/O pins: CLK_[2,3][A..N]_[0,1][p,n] |
|
Transceiver: 24 differential I/O: 32 single-ended or 16 differential |
|
|
Transceiver: 48 differential I/O: 32 single-ended or 16 differential |
|
|
Transceiver: 32 differential I/O: 60 single-ended or 30 differential |
|
|
Transceiver: 26 differential I/O: 36 single-ended or 18 differential |
|
|
Transceiver: 11 differential I/O: 22 single-ended or 44 differential |
|
|
Transceiver: 32 differential I/O: 56 single-ended or 28 differential |
|
|
Transceiver: 32 differential I/O: 52 single-ended or 26 differential |
|
|
Transceiver: 35 differential I/O: 36 single-ended or 18 differential |
|
|
Transceiver: 15 differential I/O: 48 single-ended or 14 differential |
|
|
Transceiver: 16 differential I/O: 56 single-ended or 28 differential |
|
|
Transceiver: 32 differential I/O: 96 single-ended or 48 differential |
|
|
Transceiver: 53 differential I/O: 36 single-ended or 18 differential |
|
|
Transceiver: 13 differential I/O: 68 single-ended or 34 differential |
Device | Number of Resources Available | Source of Clock Resource |
---|---|---|
All Intel® Stratix® 10 devices | 32 bidirectional programmable clock routing at the boundary of each clock sector |
For transceiver bank:
For I/O bank:
|
For more information about the clock input pins connections, refer to the pin connection guidelines.
2.1.3. Programmable Clock Routing Sources
This section describes the sources that can drive the programmable clock routing.
2.1.3.1. Dedicated Clock Input Pins
The sources of dedicated clock input pins are as follows:
- fPLL—REFCLK_GXB[L,R][1,4][C,D,E,F,G,H,I,J,K,L,M,N]_CH[B,T][p,n] from transceiver column
- I/O PLL—CLK_[2,3][A..N]_[0,1][p,n] from I/O column
You can use the dedicated clock input pins for high fan-out control signals, such as asynchronous clears, presets, and clock enables, for protocol signals through the programmable clock routing.
The dedicated clock input pins for an I/O PLL can be either differential clocks or single-ended clocks. The dedicated clock input pins for fPLL only support differential clocks and do not support single-ended clocks.
Driving a PLL over programmable clock routing can cause higher jitter at the PLL input, and the PLL is not able to fully compensate for the programmable clock routing. Intel recommends using the dedicated clock input pins for optimal performance to drive the PLLs.
2.1.3.2. Internal Logic
You can route up to eight core signals to each clock switch multiplexer, except the clock switch multiplexers at the right and left edge of the device, and the clock switch multiplexers next to the I/O banks.
2.1.3.3. DPA Clock Outputs
Each DPA clock output can drive the programmable clock routing.
2.1.3.4. Transceiver Clock Outputs
PMA and PCS TX and RX clock outputs can drive the programmable clock routing.
2.1.3.5. PLL Clock Outputs
The fPLL and I/O PLL clock outputs can drive the programmable clock routing.
2.1.4. Clock Control Features
The following figure shows the high level description of the Intel® Stratix® 10 clock control features—clock gating and clock divider. The clock from the I/O PLL output can be gated dynamically. These clock signals along with other clock sources go to the periphery distributed clock multiplexer (DCM). In the periphery DCM, the clock signal can either pass straight through, be gated by the root clock gate, or be divided by the clock divider.
The Intel® Quartus® Prime software routes the clock signal on the programmable clock routing to reach each clock sector. The clock signal can be gated in each sector by the SCLK gates. The clock enters the SCLK network followed by the row clock network, and eventually reaches the registers in the core. The LAB registers have a built-in functional clock enable feature, as shown in the following figure.
2.1.4.1. Clock Gating
2.1.4.1.1. Root Clock Gate
There is one root clock gate per I/O bank and transceiver bank. This gate is a part of the periphery DCM and is located close to the clock buffer.
The Intel® Stratix® 10 root clock gate is intended for limited clock gating scenarios where high insertion delay can be tolerated. When you use a root clock gate, set multicycle of several clock cycles between the generation of the clock gating signal in the core and the gated clock in the periphery to meet the timing requirement. For high frequency clocks that require single-cycle gating, use sector clock gates.
2.1.4.1.2. Sector Clock Gate
There are 32 SCLKs in every sector of the device. Each SCLK has a clock gate and bypassable clock gate path. The SCLK gates are controlled by clock enable inputs from the core logic. The Intel® Quartus® Prime software can route up to eight unique clock enable signals to the 32 SCLKs in a sector.
Intel recommends using the clock gate with a negative latch to provide glitch free gating on the output clock signal (outclk). The clock gate captures the enable signal (clkena) on the next rising edge of the input clock signal (inclk). The following timing diagram shows the relationship of the outclk with respect to inclk and clkena.
The clock signal going into the SCLK network in a sector can only reach the core logic in that sector. When you instantiate a SCLK gate in your design, the Intel® Quartus® Prime software automatically duplicates the SCLK gate to create a clock gate in every sector to which the clock signal is routed.
The SCLK gate is suitable for cycle-specific clock gating for high-frequency clocks. The timing of the enable path to the SCLK gate is analyzed by the Intel® Quartus® Prime software.
2.1.4.1.3. I/O PLL Clock Gate
You can dynamically gate each output counter of the Intel® Stratix® 10 I/O PLL. This provides a useful alternative to the root clock gate because the root clock gate can gate only 1 of the 9 output counters.
However, the I/O PLL clock gate is not cycle-specific. When you use the I/O PLL clock gate, expect a delay of several clock cycles between the assertion or deassertion of the clock gate and the corresponding change to the clock signal. The number of delay cycles is non-deterministic because the enable signal must be synchronized into the clock domain of the output clock, ensuring a glitch-free gate.
2.1.4.1.4. LAB Clock Gate
The Intel® Stratix® 10 LAB register has built-in clock gating functionality. The register clock enable mechanism is a hardened data feedback, as shown in the Clock Gating and Clock Divider in Intel® Stratix® 10 Clock Network diagram. The LAB clock gate offers no associated power savings because this is a purely functional clock enable.
The analysis and synthesis phases of the Intel® Quartus® Prime software infer a LAB clock gate from a behavioral description of clock gating in the register transfer level (RTL). If a physical clock gate is desired, you must instantiate it explicitly.
2.1.4.2. Clock Divider
There is one clock divider per I/O bank and transceiver bank. The clock divider is a part of the periphery DCM block and is located close to the root clock gate. The outputs of the clock divider cannot be gated by the root clock gate in the same periphery DCM block. However, this limitation does not apply to the SCLK gate. The clock divider output in the periphery DCM block can drive a SCLK gate after going through the programmable clock routing.
The clock divider has three outputs as follows:
- First output—Passes through the input clock.
- Second output—Divides the input clock by two.
- Third output—Divides the input clock by four.
These three clock outputs are edge-aligned at the output of the clock divider.
2.1.4.3. Dynamic Clock Switchover
Intel® Stratix® 10 devices do not have hard clock multiplexer blocks for dynamic clock switchover. Thus, the dynamic clock switchover logic is implemented using the soft logic in the core. Optionally, you can make the dynamic clock switchover glitch free using additional external soft logic.
2.2. PLLs Architecture and Features
2.2.1. PLL Features
Feature | Fractional PLL | I/O PLL |
---|---|---|
Integer PLL | Yes | Yes |
Fractional PLL | Yes | — |
Number of C output counter | 1 | 9 |
M counter divide factor range |
In integer mode: 8 to 127 In fractional mode: 11 to 123 |
4 to 160 |
N counter divide factor range | 1 to 31 | 1 to 110 |
C counter divide factor range | 1 to 512 | 1 to 510 |
L counter divide factors | 1, 2, 4, and 8 | — |
Dedicated external clock outputs | — | Yes |
Dedicated clock input pins | Yes | Yes |
External feedback input pin | — | Yes |
Spread-spectrum input clock tracking 2 | Yes | Yes |
Source synchronous compensation 3 | — | Yes |
Direct compensation | Yes | Yes |
Normal compensation 3 | — | Yes |
Zero-delay buffer compensation | — | Yes |
External feedback compensation | — | Yes |
LVDS compensation | — | Yes |
Voltage-controlled oscillator (VCO) output drives the DPA clock | — | Yes |
Phase shift resolution 4 | — | 78.125 ps |
Programmable duty cycle | Fixed 50% duty cycle | Yes |
Power down mode | Yes | Yes |
2.2.2. PLL Usage
fPLLs are optimized for use as transceiver transmit PLLs and for synthesizing reference clock frequencies. You can use the fPLLs to:
- Transmit clocking for transceivers
- Reduce the number of required oscillators on the board
I/O PLLs are optimized for use with memory interfaces and LVDS SERDES. You can use the I/O PLLs to:
- Reduce the number of required oscillators on the board
- Reduce the clock pins used in the FPGA by synthesizing multiple clock frequencies from a single reference clock source
- Simplify the design of external memory interfaces and high-speed LVDS interfaces
- Ease timing closure because the I/O PLLs are tightly coupled with the I/Os
- Compensate for clock network delay
- Zero delay buffering
2.2.3. PLL Architecture
2.2.4. PLL Control Signals
You can use the reset signal to control PLL operation and resynchronization, and use the locked signal to observe the status of the PLL.
2.2.4.1. Reset
The reset signal port of the IP core for I/O PLL is reset.
The reset signal is the reset or resynchronization input for each I/O PLL. The device input pins or internal logic can drive these input signals.
When the reset signal is driven high, the I/O PLL counters reset, clearing the I/O PLL output and placing the I/O PLL out-of-lock. The VCO is then set back to its nominal setting. When the reset signal is driven low again, the I/O PLL resynchronizes to its input clock source as it re-locks.
You must assert the reset signal every time the I/O PLL loses lock to guarantee the correct phase relationship between the I/O PLL input and output clocks. You can set up the I/O PLL to automatically reset (self-reset) after a loss-of-lock condition using the Intel® Quartus® Prime parameter editor.
You must include the reset signal if either of the following conditions is true:
- I/O PLL reconfiguration or clock switchover is enabled in the design.
- Phase relationships between the I/O PLL input and output clocks must be maintained after a loss-of-lock condition.
Reset the I/O PLL after the input clock is stable and within specifications, even when the self-reset feature is enabled, if either one of the following conditions occur:
- The input clock to the I/O PLL is not toggling or is unstable when the FPGA transitions into user mode.
- The I/O PLL is not able to lock to the reference clock after reconfiguring the I/O PLL.
2.2.4.2. Locked
The locked signal port of the IP core for each PLL is as follows:
- fPLL—pll_locked
- I/O PLL—locked
The lock detection circuit provides a signal to the core logic. The signal indicates when the feedback clock has locked onto the reference clock both in phase and frequency.
When PLL loses lock, the output of the PLL starts drifting out of the desired frequency. The downstream logic must be held inactive once PLL has lost lock.
2.2.5. Clock Feedback Modes
Clock feedback modes compensate for clock network delays to align the rising edge of the output clock with the rising edge of the PLL's reference clock. Select the appropriate type of compensation for the timing critical clock path in your design.
PLL compensation is not always needed. A PLL should be configured in direct (no compensation) mode unless a need for compensation is identified. Direct mode provides the best PLL jitter performance and avoids expending compensation clocking resources unnecessarily.
The default clock feedback mode is direct compensation mode.
fPLLs support only the direct compensation mode.
I/O PLLs support the following clock feedback modes:
- Direct compensation
- LVDS compensation
- Source synchronous compensation
- Normal compensation
- Zero delay buffer (ZDB) compensation
- External feedback (EFB) compensation
Normal and source synchronous compensation modes compensate for the insertion delay of a routed core clock. For Intel® Stratix® 10 devices, you can achieve core clock compensation by the following methods:
- You can route a dedicated feedback clock from the M counter in the I/O PLL to emulate the insertion delay of the compensated C counter output clock network.
- You can select Use Nondedicated Feedback Path from the IOPLL Intel® FPGA IP core which routes the compensated C counter output clock back to the I/O PLL.
Intel recommends the non-dedicated feedback mechanism because it utilizes the clock resources most efficiently. The default is dedicated feedback when you choose normal or source synchronous compensation mode in the IOPLL IP core.
2.2.5.1. Direct Compensation Mode
In direct mode, the PLL does not compensate for any clock network delays. This mode provides better jitter performance compared to other compensation modes because the clock feedback into the phase frequency detector (PFD) passes through less circuitry. Both the PLL internal- and external-clock outputs are phase-shifted with respect to the PLL clock input.
2.2.5.2. LVDS Compensation Mode
The purpose of LVDS compensation mode is to maintain the same data and clock timing relationship seen at the pins of the internal serializer/deserializer (SERDES) capture register, except that the clock is inverted (180° phase shift). Thus, LVDS compensation mode ideally compensates for the delay of the LVDS clock network, including the difference in delay between the following two paths:
- Data pin-to-SERDES capture register
- Clock input pin-to-SERDES capture register
The output counter must provide the 180° phase shift.
2.2.5.3. Source Synchronous Compensation Mode
If the data and clock signals arrive at the same time on the input pins, the same phase relationship is maintained at the clock and data ports of any IOE input register. Data and clock signals at the IOE experience similar buffer delays as long as you use the same I/O standard. Only one output clock can be compensated in source synchronous compensation mode.
Intel recommends source synchronous mode for source synchronous data transfers.
The source synchronous mode compensates for the delay of the clock network used and any difference in the delay between the following two paths:
- Data pin to the IOE register input
- Clock input pin to the PLL PFD input
The Intel® Stratix® 10 PLL can compensate multiple pad-to-input-register paths, such as a data bus when it is set to use source synchronous compensation mode.
2.2.5.4. Normal Compensation Mode
An internal clock in normal compensation mode is phase-aligned to the input clock pin. The external clock output pin has a phase delay relative to the clock input pin if connected in this mode. The Intel® Quartus® Prime Timing Analyzer reports any phase difference between the two. In normal compensation mode, the delay introduced by the clock network is fully compensated. Only one output clock can be compensated in normal compensation mode.
2.2.5.5. Zero-Delay Buffer Mode
In zero-delay buffer (ZDB) mode, the external clock output pin is phase-aligned with the clock input pin for zero delay through the device.
In this mode, you must use the same I/O standard on the input clocks and clock outputs to guarantee clock alignment at the input and output pins. You cannot use differential I/O standards on the PLL clock input or output pins.
To ensure phase alignment between the clk pin and the external clock output (CLKOUT) pin in ZDB mode, instantiate a bidirectional I/O pin in the design. The bidirectional I/O pin serves as the feedback path connecting the fbout and fbin ports of the PLL. The bidirectional I/O pin must always be assigned a single-ended I/O standard, and must not be globally promoted. The PLL uses this bidirectional I/O pin to mimic and compensate for the output delay from the clock output port of the PLL to the external clock output pin.
2.2.5.6. External Feedback Mode
In external feedback (EFB) mode, the output of the M counter (fbout) feeds back to the PLL fbin input (using a trace on the board) and becomes part of the feedback loop.
One of the dual-purpose external clock outputs becomes the fbin input pin in this mode. The external feedback input pin, fbin is phase-aligned with the clock input pin. Aligning these clocks allows you to remove clock delay and skew between devices.
In EFB mode, you must use the same I/O standard on the input clock, feedback input, and clock outputs.
2.2.6. Clock Multiplication and Division
An Intel® Stratix® 10 PLL output frequency is related to its input reference clock source by the following scale factors:
- M/(N × C) for I/O PLL
- M/(N × C × 2) for fPLL core applications
The input clock is divided by a pre-scale factor, N, and is then multiplied by the M feedback factor. The control loop drives the VCO to match fin × (M/N). When using non-dedicated feedback path in normal or source synchronous compensation mode, the control loop drives the VCO to match fin × ((M × Ci )/N), where Ci is the compensated outclk C counter value. The Intel® Quartus® Prime software automatically chooses the appropriate scale factors according to the input frequency, multiplication, and division values entered into the Intel® FPGA IP cores for I/O PLL and fPLL.
Pre-Scale Counter, N and Multiply Counter, M
Each PLL has one pre-scale counter, N, and one multiply counter, M. The M and N counters do not use duty-cycle control because the only purpose of these counters is to calculate frequency division.
Post-Scale Counter, C
Each output port has a unique post-scale counter, C. For multiple C counter outputs with different frequencies, the VCO is set to the least common multiple of the output frequencies that meets its frequency specifications. For example, if the output frequencies required from one I/O PLL are 55 MHz and 100 MHz, the Intel® Quartus® Prime software sets the VCO frequency to 1.1 GHz (the least common multiple of 55 MHz and 100 MHz within the VCO operating frequency range). Then the post-scale counters, C, scale down the VCO frequency for each output port.
Post-Scale Counter, L
The fPLL has an additional post-scale counter, L. The L counter synthesizes the frequency from its clock source using the M/(N × L) scale factor. The L counter generates a differential clock pair (0 degree and 180 degree) and drives the transceiver clock network.
Delta-Sigma Modulator
The delta-sigma modulator (DSM), together with the M multiply counter, enable the fPLL to operate in fractional mode. The DSM dynamically changes the M counter factor on a cycle-to-cycle basis. The changes in M counter factors result an average M counter factor that is non-integer.
Fractional Mode
In fractional mode, the M counter value equals the sum of the M feedback factor and the fractional value. The fractional value is equal to K/2 X , where K is an integer between 0 and (2 X – 1), and X = 32.
Integer Mode
For a fPLL operating in integer mode, M is an integer value and DSM is disabled.
The I/O PLL can only operate in integer mode.
2.2.7. Programmable Phase Shift
The programmable phase shift feature allows only the I/O PLLs to generate output clocks with a fixed phase offset.
The VCO frequency of the PLL determines the precision of the phase shift. The minimum phase shift increment is 1/8 of the VCO period. For example, if an I/O PLL operates with a VCO frequency of 1000 MHz, phase shift steps of 125 ps are possible.
The Intel® Quartus® Prime software automatically adjusts the VCO frequency according to the user-specified phase shift values entered into the IOPLL IP core parameter editor.
2.2.8. Programmable Duty Cycle
The programmable duty cycle feature allows I/O PLLs to generate clock outputs with a variable duty cycle. This feature is only supported by the I/O PLL post-scale counters, C. fPLLs do not support the programmable duty cycle feature and only have fixed 50% duty cycle.
The I/O PLL C counter value determines the precision of the duty cycle. The precision is 50% divided by the post-scale counter value. For example, if the C0 counter is 10, steps of 5% are possible for duty-cycle options from 5% to 90%. If the I/O PLL is in external feedback mode, set the duty cycle for the counter driving the fbin pin to 50%.
The Intel® Quartus® Prime software automatically adjusts the VCO frequency according to the required duty cycle that you enter in the IOPLL IP core parameter editor.
Combining the programmable duty cycle with programmable phase shift allows the generation of precise non-overlapping clocks.
2.2.9. PLL Cascading
Intel® Stratix® 10 devices support PLL-to-PLL cascading. You can cascade a maximum of two PLLs. PLL cascading synthesizes more output clock frequencies than a single PLL.
If you cascade PLLs in your design, the source (upstream) PLL must have a low-bandwidth setting, and the destination (downstream) PLL must have a high-bandwidth setting for I/O PLL and medium-bandwidth setting for fPLL. During cascading, the output of the source PLL serves as the reference clock (input) of the destination PLL. The bandwidth settings of cascaded PLLs must be different. If the bandwidth settings of the cascaded PLLs are the same, the cascaded PLLs may amplify phase noise at certain frequencies.
Intel® Stratix® 10 devices support the following PLL-to-PLL cascading modes:
- I/O-PLL-to-I/O-PLL cascading via dedicated cascade path—Upstream I/O PLL and downstream I/O PLL must be in the same I/O column.
- I/O-PLL-to-I/O-PLL cascading via core clock fabric—No restriction on locations of upstream and downstream I/O PLL.
The permit_cal input of the downstream I/O PLL must be connected to the locked output of the upstream I/O PLL in both PLL cascading modes.
The following figures show the connectivity required between the upstream and downstream I/O PLL for both the PLL cascading modes.
2.2.10. Clock Switchover
The clock switchover feature allows the I/O PLL to switch between two reference input clocks. Use this feature for clock redundancy or for a dual-clock domain application where a system turns to the redundant clock if the previous clock stops running. The design can perform clock switchover automatically when the clock is no longer toggling or based on a user control signal, extswitch.
Intel® Stratix® 10 I/O PLLs support the following clock switchover modes:
- Automatic switchover—The clock sense circuit monitors the current reference clock. If the current reference clock stops toggling, the reference clock automatically switches to inclk0 or inclk1 clock.
- Manual clock switchover—Clock switchover is controlled using the extswitch signal. When the extswitch signal goes from logic high to logic low, and stays low for at least three clock cycles for the inclk being switched to, the reference clock to the I/O PLL is switched from inclk0 to inclk1, or vice-versa.
- Automatic switchover with manual override—This mode combines automatic switchover and manual clock switchover. When the extswitch signal goes low, it overrides the automatic clock switchover function. As long as the extswitch signal is low, further switchover action is blocked.
2.2.10.1. Automatic Switchover
Intel® Stratix® 10 I/O PLLs support a fully configurable clock switchover capability.
When the current reference clock is not present, the clock sense block automatically switches to the backup clock for I/O PLL reference. You can select a clock source as the backup clock by connecting it to the inclk1 port of the I/O PLL in your design.
The clock switchover circuit sends out three status signals—clkbad0, clkbad1, and activeclock—from the I/O PLL to implement a custom switchover circuit in the logic array.
In automatic switchover mode, the clkbad0 and clkbad1 signals indicate the status of the two clock inputs. When they are asserted, the clock sense block detects that the corresponding clock input has stopped toggling. These two signals are not valid if the frequency difference between inclk0 and inclk1 is greater than 20%.
The activeclock signal indicates which of the two clock inputs (inclk0 or inclk1) is being selected as the reference clock to the I/O PLL. When the frequency difference between the two clock inputs is more than 20%, the activeclock signal is the only valid status signal.
Use the switchover circuitry to automatically switch between inclk0 and inclk1 when the current reference clock to the I/O PLL stops toggling. You can switch back and forth between inclk0 and inclk1 any number of times when one of the two clocks fails and the other clock is available.
For example, in applications that require a redundant clock with the same frequency as the reference clock, the switchover state machine generates a signal (clksw) that controls the multiplexer select input. In this case, inclk1 becomes the reference clock for the I/O PLL.
When using automatic clock switchover mode, the following requirements must be satisfied:
- Both clock inputs must be running when the FPGA is configured.
- The period of the two clock inputs can differ by no more than 20%.
- The input clocks must meet the input jitter specifications and I/O standard specifications.
Glitches in the input clock may be seen as a greater than 20% difference in frequency between the input clocks.
If the current clock input stops toggling while the other clock is also not toggling, switchover is not initiated and the clkbad[0..1] signals are not valid. If both clock inputs are not the same frequency, but their period difference is within 20%, the clock sense block detects when a clock stops toggling. However, the I/O PLL may lose lock after the switchover is completed and needs time to relock.
2.2.10.2. Automatic Switchover with Manual Override
In automatic switchover with manual override mode, you can use the extswitch signal for user- or system-controlled switch conditions. You can use this mode for same-frequency switchover, or to switch between inputs of different frequencies.
For example, if inclk0 is 66 MHz and inclk1 is 200 MHz, you must control switchover using the extswitch signal. The automatic clock-sense circuitry cannot monitor clock input (inclk0 and inclk1) frequencies with a frequency difference of more than 100% (2×).
This feature is useful when the clock sources originate from multiple cards on the backplane, requiring a system-controlled switchover between the frequencies of operation.
You must choose the backup clock frequency and set the M, N, C, L, and K counters so that the VCO operates within the recommended operating frequency range. The Intel® Quartus® Prime software notifies you if a given combination of inclk0 and inclk1 frequencies cannot meet this requirement.
In automatic override with manual switchover mode, the activeclock signal inverts after the extswitch signal transitions from logic high to logic low. Since both clocks are still functional during the manual switch, neither clkbad signal goes high. Because the switchover circuit is negative-edge sensitive, the rising edge of the extswitch signal does not cause the circuit to switch back from inclk1 to inclk0. When the extswitch signal goes low again, the process repeats.
The extswitch signal and automatic switch work only if the clock being switched to is available. If the clock is not available, the state machine waits until the clock is available.
2.2.10.3. Manual Clock Switchover
In manual clock switchover mode, the extswitch signal controls whether inclk0 or inclk1 is selected as the input clock to the I/O PLL. By default, inclk0 is selected.
A clock switchover event is initiated when the extswitch signal transitions from logic high to logic low, and is held low for at least three inclk cycles for the inclk clock being switched to.
You must bring the extswitch signal back high again to perform another switchover event. If you do not require another switchover event, you can leave the extswitch signal in a logic low state after the initial switch.
If inclk0 and inclk1 are different frequencies and are always running, the extswitch signal minimum low time must be greater than or equal to three of the slower frequency inclk0 and inclk1 cycles.
You can delay the clock switchover action by specifying the switchover delay in the Intel® FPGA IP cores for the I/O PLL. When you specify the switchover delay, the extswitch signal must be held low for at least three inclk cycles for the inclk being switched to plus the number of the delay cycles that has been specified to initiate a clock switchover.
2.2.11. PLL Reconfiguration and Dynamic Phase Shift
Intel® Stratix® 10 devices support PLL reconfiguration and dynamic phase shift with the following features:
- PLL reconfiguration—I/O PLL and fPLL are able to reconfigure the M, N, and C counters. Only the fPLL supports reconfiguration of the fractional settings.
- Dynamic phase shift—Only the I/O PLL can perform positive or negative phase shift. Able to shift multiple phase steps each time, where one phase step is equal to 1/8 of the VCO period.
2.2.12. PLL Calibration
I/O PLLs include both analog and digital blocks that require calibration to compensate for process, voltage, and temperature (PVT) variations. Intel® Stratix® 10 uses the I/O manager to perform calibration routines.
There are two main types of calibration.
- Power-up calibration—Initiates automatically at device power-up and runs during device configuration.
- User calibration—If you perform dynamic reconfiguration or change the reference clock frequency of the I/O PLL, you must perform user recalibration. You must enable the required calibration sequence.
To successfully complete the calibration process, OSC_CLK_1 clocks and all reference clocks driving the I/O PLLs must be stable and free running at the start of FPGA configuration. If clock switchover is enabled, both reference clocks must be present for calibration. During user mode, when the I/O PLL does not detect a reference clock during configuration, calibration attempts continue periodically. After calibration has completed, the I/O PLL is locked automatically.
2.2.12.1. Power-Up Calibration
After device power-up, the I/O manager automatically initiates the calibration process. The process continues during device programming.
You must enable the permit_cal signal from the IOPLL IP core to delay the power-up calibration in I/O PLL if the reference clock is not stable before device configuration. Set permit_cal = 0 upon power up until the reference clock is stable and operating at the correct frequency. Then, set permit_cal = 1 to initiate the power-up calibration. You must ensure that the permit_cal signal remains high once asserted.
2.2.12.2. User Calibration
The I/O PLL must be recalibrated for any of the following conditions after device power up:
- Dynamic I/O PLL reconfiguration that changes the M or N counter settings is performed.
- Change of the reference clock frequency to the I/O PLL.
Recalibration is not necessary when using clock switchover to a secondary reference clock with a different frequency than the primary reference clock. The I/O PLL stores the calibration settings for both reference clocks after power-up calibration.
To perform the recalibration of the I/O PLL, you must enable the IOPLL Reconfig Intel® FPGA IP core to enable the recalibration mode.
3. Intel Stratix 10 Clocking and PLL Design Considerations
3.1. Guideline: Clock Switchover
When implementing clock switchover in Intel® Stratix® 10 I/O PLLs, refer to the following guidelines:
- Automatic clock switchover requires that the inclk0 and inclk1 frequencies be within 20% of each other. Failing to meet this requirement causes the clkbad0 and clkbad1 signals to not function properly.
- When using manual clock switchover, the difference between inclk0 and inclk1 can be more than 100% (2×). However, differences in frequency, phase, or both, of the two clock sources may cause the I/O PLL to lose lock. Resetting the I/O PLL ensures that you maintain the correct phase relationships between the input and output clocks.
- Both inclk0 and inclk1 must be running when the extswitch signal goes low to initiate the manual clock switchover event. Failing to meet this requirement causes the clock switchover to not function properly.
- Applications that require a clock switchover feature and a small frequency drift must use a low-bandwidth I/O PLL. When referencing input clock changes, the low-bandwidth I/O PLL reacts more slowly than a high-bandwidth I/O PLL. When switchover happens, a low-bandwidth I/O PLL propagates the stopping of the clock to the output more slowly than a high-bandwidth I/O PLL. However, be aware that the low-bandwidth I/O PLL also increases lock time.
- After a switchover occurs, there may be a finite resynchronization period for the I/O PLL to lock onto a new clock. The time it takes for the I/O PLL to relock depends on the I/O PLL configuration.
- If the phase relationship between the input clock to the I/O PLL and the output clock from the I/O PLL is important in your design, assert the reset signal for at least 10 ns after performing a clock switchover. Wait for the locked signal to go high and be stable before re-enabling the output clocks from the I/O PLL.
- The VCO frequency gradually decreases when the current clock is lost and then increases as the VCO locks on to the backup clock, as shown in the following figure.
3.2. IP Core Constraints
To implement the fPLL IP core, you must adhere to the following constraints:
- You must use create_clock constraints on fPLL reference clocks on the project's top-level Synopsys Design Constraints File (.sdc).
- Any SDC design constraints referring to transceiver clocks must be listed after the transceiver Native PHY .sdc file constraints.
- fPLL output clocks have no phase relationship to the reference clock when utilizing the fPLL output clocks for core usage. The fPLL output clocks of the clock divider are still in phase with each other, however.
To implement the IOPLL IP core, you must adhere to the following constraints:
- Any SDC design constraints referring to the I/O PLL clocks must be listed after the SDC constraints for the IOPLL IP core.
- For Intel® Quartus® Prime software version 18.1 or later, you may see error warning message for design with encrypted IOPLL IP core. The auto-generated .sdc files of the IOPLL IP core are not supported if you use encryption. You must manually create the .sdc file using create_clock and create_generated_clock to replace the auto-generated .sdc file in the design for refclk and output clocks.
3.3. Guideline: Resetting the PLL
To reset the PLL, refer to the following guidelines:
- When changing the M counter, N counter, or loop filter settings, the I/O PLL may lose and regain lock. To maintain the appropriate phase relationship between the reference clock and output clocks, assert the areset signal to reset the I/O PLL after reconfiguration is complete. Intel recommends always resetting the I/O PLL after any reconfiguration operation to the M counter, N counter, or loop filter settings.
- When changing the C counter settings, you may lose the expected phase relationship between the C counters. Assert the areset signal after reconfiguration is complete to restore the expected phase relationship. Reset is not required if the phase relationships are not important to your application.
- Resetting the I/O PLL does not modify the counter or loop filter settings. However, resetting the I/O PLL undoes any dynamic phase shift operations that were performed. After the I/O PLL is reset, the phase shift on the C counters is restored to the originally programmed settings.
3.4. Guideline: Configuration Constraints
The I/O PLL configuration must obey the following constraints:
- The phase frequency detector (PFD) and VCO each have a legal frequency range of operation.
- The loop filter settings must be appropriate for the M counter value and user-selected bandwidth mode.
If any of these configuration constraints are violated, the I/O PLL may fail to lock or may exhibit poor jitter performance.
3.5. Guideline: Timing Closure
For timing closure, refer to the following guidelines:
- Reconfiguring a PLL's counter and loop filter settings changes both the output frequency and the clock uncertainty of that I/O PLL. Dynamic phase shift only affects the output clock phase.
- The Timing Analyzer in the Intel® Quartus® Prime software performs timing analysis for the initial PLL settings only. You must verify that your design closes timing after dynamic reconfiguration or dynamic phase shift.
- Intel recommends compiling the I/O PLL designs with each intended configuration setting to determine the variation in the clock with the I/O PLL settings.
3.6. Guideline: I/O PLL Reconfiguration
To reconfigure the I/O PLL, refer to the following guidelines:
- If the reference clock frequency changes, you must recalibrate the I/O PLL using the IOPLL Intel® FPGA IP core.
- The I/O PLL reconfiguration interface must have a free running mgmt_clk signal. The I/O PLL dynamic phase shift interface must have a free running scanclk signal. These interfaces eliminate the need to precisely control the start and stop of mgmt_clk and scanclk signals.
- The I/O PLL can be reconfigured with .mif streaming mode and advanced mode using the IOPLL Reconfig Intel® FPGA IP core. Intel recommends using the .mif streaming mode.
- Use caution when reconfiguring an I/O PLL with a non-zero phase shift setting. Modifying the M counter or N counter settings does not change the relative phase shift (in percent), but alters the absolute phase shift (in picoseconds). Modifying the C counter settings does not change the absolute phase shift, but modifies the relative phase shift.
3.7. Guideline: I/O PLL Jitter Performance
To achieve the Intel® Stratix® 10 I/O PLL clock output jitter performance as specified in the Intel® Stratix® 10 Device Datasheet, adhere to the maximum allowable number of unterminated simultaneously switching output (SSO) pins, such as LVTTL and LVCMOS, within the I/O bank (where the PLL output clock resides).
SSO Pin Current Strength (mA) | Maximum Allowable Number of SSO Pins |
---|---|
16 | 17 |
12 | 21 |
10 | 27 |
8 | 36 |
If you use more than the maximum allowable unterminated SSO pins, additional jitter beyond the PLL clock output jitter specification is induced to the PLL clock output.
SSO Pin Current Strength (mA) | Jitter Increment per SSO Pin (ps/pin) |
---|---|
16 | 8 |
12 | 7 |
10 | 6 |
8 | 4 |
When you use a combination of different current strength, calculate the maximum allowable number of SSO pins according to the strongest current strength used. The jitter increment value per SSO pin should then be calculated using the strongest current strength setting from the remaining SSO pins (after deducting the maximum allowable number of SSO pins from the total SSO pins). For example, if the design has 19 pins with current strength 16 mA, 5 pins with current strength 12 mA, and 2 pins with current strength 10 mA, the maximum allowable number of SSO pins for this design is 17, and the jitter increment per SSO pin is 8 ps/pin. Total additional jitter induced is equivalent to [(19 + 5 + 2) – 17] × 8 = 72 ps.
3.8. Guideline: Clock Gating
Both sector clock gate and root clock gate have similar skews. To achieve higher performance when transferring between gated and non-gated clocks and vice-versa, refer to the following guidelines:
- Minimize the size of clock region because smaller clock delays have lower skew.
- Ensure that both gated and non-gated clocks have similar sizes.
- Minimize logic on paths between gated and non-gated clocks to achieve better timing margin to compensate for the higher skews.
4. Intel Stratix 10 Clocking and PLL Implementation Guides
If you are looking for the fPLL IP core, refer to the Intel Stratix 10 L- and H-Tile Transceiver PHY User Guide.
4.1. Clock Control Intel FPGA IP Core
The Clock Control IP core provides clock control features such as enabling entry to the clock network, clock multiplexing, clock gating, and clock division for the Intel® Stratix® 10 devices.
4.1.1. Release Information for Clock Control Intel FPGA IP
IP versions are the same as the Intel® Quartus® Prime Design Suite software versions up to v19.1. From Intel® Quartus® Prime Design Suite software version 19.2 or later, IP cores have a new IP versioning scheme.
The IP version (X.Y.Z) number may change from one Intel Quartus Prime software version to another. A change in:
- X indicates a major revision of the IP. If you update your Intel Quartus Prime software, you must regenerate the IP.
- Y indicates the IP includes new features. Regenerate your IP to include these new features.
- Z indicates the IP includes minor changes. Regenerate your IP to include these changes.
Item | Description |
---|---|
IP Version | 20.0.0 |
Intel® Quartus® Prime Version | 20.3 |
Release Date | 2020.09.28 |
4.2. IOPLL Intel FPGA IP Core
The IOPLL IP core allows you to configure the settings of the Intel® Stratix® 10 I/O PLL.
The IOPLL IP core supports the following features:
- Supports six different clock feedback modes: direct, external feedback, normal, source synchronous, zero delay buffer, and LVDS mode.
- Generates up to nine clock output signals for the Intel® Stratix® 10 device.
- Switches between two reference input clocks.
- Supports adjacent PLL (adjpllin) input to connect with an upstream PLL in PLL cascading mode.
- Generates the Memory Initialization File (.mif) and allows PLL dynamic reconfiguration.
- Supports PLL dynamic phase shift.
4.2.1. Release Information for IOPLL Intel FPGA IP
IP versions are the same as the Intel® Quartus® Prime Design Suite software versions up to v19.1. From Intel® Quartus® Prime Design Suite software version 19.2 or later, IP cores have a new IP versioning scheme.
The IP version (X.Y.Z) number may change from one Intel Quartus Prime software version to another. A change in:
- X indicates a major revision of the IP. If you update your Intel Quartus Prime software, you must regenerate the IP.
- Y indicates the IP includes new features. Regenerate your IP to include these new features.
- Z indicates the IP includes minor changes. Regenerate your IP to include these changes.
Item | Description |
---|---|
IP Version | 19.3.1 |
Intel® Quartus® Prime Version | 20.3 |
Release Date | 2020.09.28 |
4.2.2. .mif File Generation
You can generate the .mif files in the IOPLL IP core parameter editor.
4.2.2.1. Generating a New .mif File
To generate a new .mif file containing a single I/O PLL configuration, follow these steps:
- At the Dynamic Reconfiguration tab, select Enable dynamic reconfiguration of PLL.
- For MIF Generation Options, select Generate New MIF File.
- For Path of New MIF file, specify a file name.
- For Name of Current Configuration, specify the name of the current configuration of the I/O PLL.
- Click Create MIF File.
4.2.2.2. Adding Configurations to Existing .mif File
You can append new configurations to an existing .mif file. To store more configurations in a .mif file, follow these steps:
- At the Dynamic Reconfiguration tab, select Enable dynamic reconfiguration of PLL.
- For MIF Generation Options, select Add Configuration to Existing MIF File.
- For Path of New MIF file, specify a file name.
- For Name of Current Configuration, specify the name of the new configuration of the I/O PLL.
- Click Append to MIF File.
4.2.3. IP-XACT File Generation
You can generate the IP-XACT files in the IOPLL IP core parameter editor. You can use the IP-XACT files to determine addresses of reconfigurable bits in the IOPLL IP core.
4.2.3.1. Generating a New IP-XACT File
To generate a new IP-XACT file, follow these steps:
- On the IOPLL Intel FPGA IP dialog box, click Generate HDL.
- Ensure either Verilog or VHDL is selected for the Create HDL design files for synthesis option. Click Generate to generate the IP-XACT file.
4.2.4. Implementing I/O PLL Dynamic Phase Shift in the IOPLL IP Core
You can use the IOPLL IP core to perform phase shifting directly through the dynamic phase shift ports.
4.2.4.1. I/O PLL Dynamic Phase Shift Operation
To perform dynamic phase shift operation for an I/O PLL in the IOPLL IP core, follow these steps:
- Set the value for updn, cntsel[4..0], and num_phase_shift[2..0] ports.
- Assert phase_en port for at least two scanclk cycles.
Each phase_en pulse indicates one dynamic phase shift operation. The phase_done output goes low to indicate that dynamic phase shift is in progress. You can only assert the phase_en signal after the phase_done signal goes from low to high.
The updn, cntsel[4..0], and num_phase_shift[2..0] ports are synchronous to the scanclk cycle.
When the phase_done signal transitions from high to low, the phase_done signal is synchronous to the rising edge of the scanclk signal. The transition from low to high is asynchronous to the scanclk signal.
Depending on the VCO and scanclk frequency, the low time of the phase_done signal may be greater than or less than one scanclk cycle.
4.2.5. Design Example
You must install the Intel® Quartus® Prime software version 17.1 or later. The software must be installed on a Windows* or Linux* computer that meets the Intel® Quartus® Prime software minimum requirements.
4.2.5.1. Design Example: Dynamic Phase Shift Using IOPLL IP Core
This design example uses the same design as "Design Example 3: Dynamic Phase Shift Using IOPLL Reconfig IP Core" without using the IOPLL Reconfig Intel® FPGA IP core. This design example demonstrates the implementation of the I/O PLL dynamic phase shift directly through the IOPLL IP core.
To run the test with this design example, perform these steps:
- Download and restore the iopll-dynamic-phase-shift.qar file.
- Change the device and pin assignments of the design example to match your hardware.
- Recompile the design example. Ensure that the design example does not contain any timing violation after recompilation.
- Open the AN.stp file and program the device with top.sof.
- Assert a high pulse on reset_SM signal to start the I/O PLL dynamic phase shift reconfiguration operation.
4.3. IOPLL Reconfig Intel Stratix 10 FPGA IP Core
You can use Intel® Stratix® 10 devices to implement phase-locked loop (PLL) reconfiguration and dynamic phase shift for I/O PLLs.
The Intel® Stratix® 10 I/O PLL supports dynamic reconfiguration when the device is in user mode. With the dynamic reconfiguration feature, you can reconfigure the I/O PLL settings in real time. You can change the divide settings of the PLL counters and the PLL bandwidth settings (loop filter setting and charge pump setting) through an Avalon® Memory-Mapped ( Avalon® -MM) interface in the IOPLL Reconfig IP core, without the need to reconfigure the entire FPGA. The Intel® Stratix® 10 I/O PLL uses divide counters (N, M, and C counters) and a voltage-controlled oscillator (VCO) to synthesize the desired phase and frequency output.
You can use the IOPLL Reconfig IP core as follows:
- Memory Initialization File (.mif)
streaming reconfiguration
- Allows the I/O PLL reconfiguration using predefined settings saved in an on-chip ROM. You can store many unique PLL configurations in a single ROM.
- The .mif file is generated automatically by the IOPLL IP core. Using the generated .mif file during .mif streaming reconfiguration ensures the legality of the new configuration.
- Intel recommends using this reconfiguration method.
- Advanced mode reconfiguration
- This method of reconfiguration is for advanced users. You must ensure the reconfigured PLL settings are within the legal range.
- Enable the Advanced Reconfiguration option from the IOPLL Reconfig IP core to reconfigure the individual I/O PLL registers.
- This method is error prone and may lead to the I/O PLL being reconfigured into an illegal configuration if the reconfiguration is done incorrectly.
- Recalibration of the I/O PLL using .mif
- Perform recalibration of the I/O PLL without any reconfiguration.
- Trigger recalibration if the reference clock frequency changes.
- I/O PLL clock gating
- Gate and un-gate I/O PLL output clock 0 to output clock 7 of the I/O PLL.
You can perform dynamic phase shift using the IOPLL Reconfig IP core.
4.3.1. Release Information for IOPLL Reconfig Intel FPGA IP
IP versions are the same as the Intel® Quartus® Prime Design Suite software versions up to v19.1. From Intel® Quartus® Prime Design Suite software version 19.2 or later, IP cores have a new IP versioning scheme.
The IP version (X.Y.Z) number may change from one Intel Quartus Prime software version to another. A change in:
- X indicates a major revision of the IP. If you update your Intel Quartus Prime software, you must regenerate the IP.
- Y indicates the IP includes new features. Regenerate your IP to include these new features.
- Z indicates the IP includes minor changes. Regenerate your IP to include these changes.
Item | Description |
---|---|
IP Version | 19.4.0 |
Intel® Quartus® Prime Version | 20.2 |
Release Date | 2020.06.22 |
4.3.2. Implementing I/O PLL Reconfiguration in the IOPLL Reconfig IP Core
You can enable the PLL reconfiguration circuitry for the I/O PLL through the Avalon® -MM interface in the IOPLL Reconfig IP core.
4.3.2.1. Connectivity between the IOPLL and IOPLL Reconfig IP Cores
4.3.2.2. Connecting the IOPLL and IOPLL Reconfig IP Cores
To connect the IOPLL and IOPLL Reconfig IP cores in your design, follow these steps:
- Connect the reconfig_to_pll[29..0] bus on the IOPLL Reconfig IP core to the reconfig_to_pll[29..0] bus on the IOPLL IP core.
- Connect the reconfig_from_pll[10..0] bus on the IOPLL Reconfig IP core to the reconfig_from_pll[10..0] bus on the IOPLL IP core.
- Connect the mgmt_clk port to a valid clock source.
- Connect the mgmt_reset port, mgmt_waitrequest port, mgmt_read port, mgmt_write port, mgmt_readdata[7..0] bus, mgmt_writedata[7..0] bus, and mgmt_address[9..0] bus to user control logic to perform read and write operations.
4.3.3. IOPLL Reconfig IP Core Reconfiguration Modes
The IOPLL Reconfig IP core has four functional reconfiguration modes. The reconfiguration operation mode is based on the setting in the mgmt_address[9:8] bit.
Reconfiguration Mode | mgmt_address[9:8] |
---|---|
.mif streaming reconfiguration | 2'b 00 |
Advanced mode reconfiguration | 2'b 01 |
Clock gating reconfiguration | 2'b 10 |
Dynamic phase shift reconfiguration | 2'b 11 |
After performing dynamic reconfiguration on the I/O PLL that changes the M counter, N counter, bandwidth setting, or charge pump current, the I/O PLL must be recalibrated. For .mif streaming reconfiguration, the recalibration is done automatically. For advanced mode reconfiguration, you must manually trigger the recalibration of the I/O PLL. Recalibration is not needed for clock gating and dynamic phase shift reconfiguration.
4.3.3.1. .mif Streaming Reconfiguration
To perform .mif streaming reconfiguration, follow these steps:
- Set mgmt_address[9:8] = 2’b00 to choose the .mif streaming mode and set mgmt_writedata[4:0] to the index of the desired configuration in the .mif file.
- To start the .mif streaming reconfiguration on the I/O PLL, assert the mgmt_write signal for one mgmt_clk cycle. mgmt_waitrequest is asserted by the IOPLL Reconfig IP core while .mif streaming is in progress.
- After the reconfiguration is complete, the mgmt_waitrequest signal is de-asserted.
- In the IOPLL Reconfig IP core parameter editor, select the Assert waitrequest until IOPLL has locked option for the I/O PLL to lock. Otherwise, you can wait for the I/O PLL to lock to ensure the I/O PLL reconfiguration is complete.
Recalibration is done automatically for .mif streaming reconfiguration. If you want to manually trigger recalibration using .mif file, follow the steps in the Recalibration Using .mif section.
4.3.3.1.1. Recalibration Using .mif
Recalibration using .mif only allows you to recalibrate the I/O PLL but not to reconfigure the I/O PLL. In the IOPLL Reconfig IP core, enable Recalibration Mode. When the recalibration is selected, a recalibration.mif file is generated automatically for the recalibration operation.
To perform I/O PLL recalibration using .mif, follow these steps:
- Set mgmt_address[9:8] = 2’b00 to choose the .mif mode and set mgmt_writedata[4:0] = 2'b00.
- To start the recalibration using .mif on the I/O PLL, assert the mgmt_write signal for one mgmt_clk cycle. mgmt_waitrequest is asserted by the IOPLL Reconfig IP core while recalibration is in progress.
- After the recalibration is complete, the mgmt_waitrequest signal is deasserted.
4.3.3.2. Advanced Mode Reconfiguration
Advanced mode reconfiguration is only recommended for advanced users. This reconfiguration mode has several limitations and can cause the I/O PLL to lose lock and can lead to device reliability problems if you set the configuration parameters to the illegal configuration settings. Intel recommends using the .mif streaming reconfiguration.
The limitations of using the advanced mode reconfiguration are as follows:
- You must ensure that the configuration setting is a legal value so that the I/O PLL has a legal configuration. To ensure your configuration is legal, refer to the IOPLL IP Core Parameters - Advanced Parameters Tab table for the correct configuration settings.
- If the value to be reconfigured makes up only a part of one byte in the I/O PLL’s internal memory, you must perform a read-modify-write operation to not overwrite the remaining bits of the byte.
- You must manually trigger recalibration of the I/O PLL after the advanced mode reconfiguration.
To perform I/O PLL reconfiguration using advanced mode, follow these steps:
- Enable the Advanced Reconfiguration option in the IOPLL Reconfig IP core.
- Set mgmt_address[9:8] = 2’b01 to choose the advanced mode reconfiguration.
-
Set the address bus value for mgmt_address[7:0] and the data bus value for mgmt_writedata [7:0] as the desired PLL
setting.
For more details, refer to the Address Bus and Data Bus Settings for Advanced Mode Reconfiguration table.
- Assert the mgmt_write signal for one mgmt_clk cycle.
- Repeat step 1 until step 3 to set address bus and data bus value for the desired I/O PLL reconfiguration setting.
-
After the I/O PLL reconfiguration is complete, you must manually trigger the
I/O PLL recalibration.
For more details about the I/O PLL recalibration, refer to the Recalibration Using Advanced Mode section.
4.3.3.2.1. Recalibration Using Advanced Mode
To perform I/O PLL recalibration using advanced mode, follow these steps:
- Set mgmt_address[9:8] = 2’b01 to choose the advanced mode.
- Set the mgmt_writedata[6] to 1’b1 on mgmt_address[7:0] = 8’b01001001 by performing the read-modify-write operation.
- Set mgmt_address[7:0] = 8’b01001010 and mgmt_wriredata[7:0] = 8’b00000011 to enable the calibration interface.
4.3.3.3. Clock Gating Reconfiguration
You can gate (disable) and un-gate (enable) I/O PLL output clock 0 to output clock 7 of the I/O PLL. It is easily done by writing one byte to the IOPLL Reconfig IP core, with one bit corresponding to each of the I/O PLL output clocks.
To perform clock gating reconfiguration, follow these steps:
- Set mgmt_address[9:8] to 2’b10 to select clock gating mode and set mgmt_writedata[7:0] to indicate desired output clock to be gated.
- To start the clock gating reconfiguration on the I/O PLL, assert the mgmt_write signal for one mgmt_clk cycle.
- The gating changes may not come into effect for multiple clock cycles after mgmt_waitrequest has been de-asserted.
4.3.3.4. Dynamic Phase Shift Reconfiguration
The dynamic phase shifts reconfiguration can determine the number of shifts, the direction of the phase shift and the output clock to be shifted.
To perform dynamic phase shift reconfiguration through the IOPLL Reconfig IP core, follow these steps:
- Set mgmt_address[9:8] to 2’b11 to select dynamic phase shift reconfiguration mode.
- set mgmt_writedata[7:0] to indicate the desired number of phase shift, the direction of phase shift, and the desired counter to be shifted.
- To start the dynamic phase shift reconfiguration on the I/O PLL, assert the mgmt_write signal for one mgmt_clk cycle. This signal is the equivalent of the phase_en signal on the I/O PLL.
- After the dynamic phase shift is complete, the mgmt_waitrequest signal is de-asserted.
4.3.4. Design Examples
You must install the Intel® Quartus® Prime software version 17.1 or later. The software must be installed on a Windows* or Linux* computer that meets the Intel® Quartus® Prime software minimum requirements.
4.3.4.1. Design Example 1: .mif Streaming Reconfiguration Using IOPLL Reconfig IP Core
This design example uses a 1SG280LU3F50E2VGS1 device to demonstrate the implementation of the I/O PLL reconfiguration through .mif streaming using the IOPLL Reconfig IP core. This design example consists of the IOPLL IP core, IOPLL Reconfig IP core, and In-System Sources & Probes Intel® FPGA IP core.
The I/O PLL synthesizes two output clocks of 400 MHz with 0 ps phase shift and 200 MHz with 0 ps phase shift on counter C0 output and counter C1 output respectively at medium bandwidth. The input reference clock is 50 MHz.
The IOPLL Reconfig IP core connects to a state machine to perform the I/O PLL .mif streaming reconfiguration operation. A high pulse on the reset_SM input through the In-System Sources & Probes IP core triggers the I/O PLL reconfiguration operation. After the I/O PLL reconfiguration operation is complete, the I/O PLL operates in the following configuration at medium bandwidth:
- 100 MHz with 0 ps phase shift on counter C0 output
- 100 MHz with 0 ps phase shift on counter C1 output
To run the test with this design example, perform these steps:
- Download and restore the iopll-reconfig-mif-streaming.qar file.
- Change the device and pin assignments of the design example to match your hardware.
- Recompile the design example. Ensure that the design example does not contain any timing violation after recompilation.
- Open the AN.stp file and program the device with top.sof.
- Assert a high pulse on the reset_SM signal to start the I/O PLL reconfiguration operation.
4.3.4.2. Design Example 2: Advanced Mode Reconfiguration Using IOPLL Reconfig IP Core
This design example uses a 1SX280LU2f50E2VGS2 device to demonstrate the implementation of the I/O PLL reconfiguration in advanced mode using the IOPLL Reconfig IP core. This design example consists of the IOPLL IP core, IOPLL Reconfig IP core, and In-System Sources & Probes IP core.
The I/O PLL synthesizes two output clocks of 400 MHz and 200 MHz on counter C0 output and counter C1 output respectively at medium bandwidth. The input reference clock is 50 MHz.
The IOPLL Reconfig IP core connects to a state machine to perform I/O PLL reconfiguration operation. A high pulse on the reset_SM input through In-System Sources & Probes IP core triggers the I/O PLL reconfiguration operation. After the I/O PLL reconfiguration operation is complete, the I/O PLL operates in the following configuration at medium bandwidth:
- 100 MHz on counter C0 output
- 100 MHz on counter C1 output
The state machine initiates the I/O PLL recalibration process when the I/O PLL reconfiguration operation is complete.
To run the test with this design example, perform these steps:
- Download and restore the iopll-reconfig-advanced-mode.qar file.
- Change the device and pin assignments of the design example to match your hardware.
- Recompile the design example. Ensure that the design example does not contain any timing violation after reconfiguration.
- Open the AN.stp file and program the device with top.sof.
- Assert a high pulse on the mgmt_reset signal to reset the IOPLL Reconfig IP core.
- Assert a high pulse on the reset_SM signal to start the I/O PLL reconfiguration operation.
4.3.4.3. Design Example 3: Clock Gating Reconfiguration Using IOPLL Reconfig IP Core
This design example uses a 1SG280LU3F50E2VGS1 device to demonstrate the implementation of the I/O PLL clock gating reconfiguration using the IOPLL Reconfig IP core. This design example consists of the IOPLL IP core, IOPLL Reconfig IP core, and In-System Sources & Probes IP core.
The I/O PLL synthesizes eight output clocks of 200 MHz each. The input reference clock is 50 MHz.
The IOPLL Reconfig IP core connects to a state machine to perform the I/O PLL clock output gating. A high pulse on the reset_SM input through the In-System Sources & Probes IP core triggers the I/O PLL reconfiguration operation. After the I/O PLL reconfiguration operation is complete, outclk0 is ungated and outclk1 is gated.
To run the test with this design example, perform these steps:
- Download and restore the iopll-reconfig-clock-gating.qar file.
- Change the device and pin assignments of the design example to match your hardware.
- Recompile the design example. Ensure that the design example does not contain any timing violation after recompilation.
- Open the AN.stp file and program the device with top.sof.
- Assert a high pulse on the reset_SM signal to start the I/O PLL clock gating reconfiguration operation.
4.3.4.4. Design Example 4: Dynamic Phase Shift Using IOPLL Reconfig IP Core
This design example uses a 1SG280LU3F50E2VGS1 device to demonstrate the implementation of the I/O PLL dynamic phase shift reconfiguration using the IOPLL Reconfig IP core. This design example consists of the IOPLL IP core, IOPLL Reconfig IP core, and In-System Sources & Probes IP core.
The I/O PLL synthesizes two output clocks of 200 MHz with 0 ps phase shift on counter C0 output and counter C1 output at medium bandwidth. The input reference clock is 50 MHz.
The IOPLL Reconfig IP core connect to a state machine to perform the I/O PLL dynamic phase shift operation. A high pulse on the reset_SM input through the In-System Sources & Probes IP core triggers the I/O PLL dynamic phase shift operation. After the I/O PLL dynamic phase shift operation is complete, counter C1 is phase shifted 89 ps for one positive phase shift step.
To run the test with this design example, perform these steps:
- Download and restore the iopll-reconfig-dynamic-phase-shift.qar file.
- Change the device and pin assignments of the design example to match your hardware.
- Recompile the design example. Ensure that the design example does not contain any timing violation after recompilation.
- Open the AN.stp file and program the device with top.sof.
- Assert a high pulse on the reset_SM signal to start the I/O PLL dynamic phase shift reconfiguration operation.
5. Clock Control Intel FPGA IP Core References
5.1. Clock Control IP Core Parameters
Parameter | Legal Value | Description |
---|---|---|
Number of Clock Inputs | 1, 2, or 4 |
Specify the number of input clock sources for the clock control block. You can specify up to four clock inputs. Clock multiplexing in Intel® Stratix® 10 devices is implemented using soft logic in the core. |
Ensure glitch free clock switchover | On or Off |
Turn on this option to implement a glitch-free switchover when you use multiple clock inputs. You must ensure the currently selected clock is running before switching to another source. If the selected clock is not running, you cannot switch to the new clock source using the glitch-free switchover implementation. By default, the clkselect port is set to 00. You must apply a clock to inclk0x to read the values on the clkselect ports. This feature will be available in a future release. |
Clock Enable | On or Off | Turn on this option if you want to gate your clock output with an enable signal. This option disables the option to use clock division. |
Clock Enable Type | Root Level or Distributed Sector Level | Select the clock gates located in the periphery or the gates located in the sector. For more information about the clock gates, refer to the Clock Gating section. |
Enable Register Mode | Negative Latch or None | Specify if the enable signal should be latched. |
Clock Divider | On or Off | Turn on this option if you want to use the clock division block in the periphery. |
Clock Divider Output Ports | Divide 1x, Divide 1x and 2x, or Divide 1x, 2x and 4x | Specify the combination of passing your clock through, dividing your clock by 2, or dividing your clock by 4. |
5.2. Clock Control IP Core Ports and Signals
Port Name | Description |
---|---|
inclk | Input signal to the clock network. |
inclk0x, inclk1x, inclk2x, inclk3x | Input signals to the clock network based on the value selected for the Number of Clock Inputs parameter. |
clkselect[] |
Input that dynamically selects the clock source to drive the clock network that is driven by the clock buffer. Input port [1 DOWNTO 0] wide. The following list shows the signal selection for the clkselect[] value:
|
outclk | Output of the Clock Control IP core when Clock Divider option is not selected. |
ena | Clock enable of the clock gate block. This signal is active-high. |
clock_div1x, clock_div2x, clock_div4x | Outputs of the Clock Control
IP core when the Clock
Divider option is selected. The exact combination of
ports exposed depends on the value specified for the Clock Divider Output Ports
parameter.
|
6. IOPLL Intel FPGA IP Core References
6.1. IOPLL IP Core Parameters
The IOPLL IP core parameter editor appears in the PLL category of the IP Catalog.
6.1.1. IOPLL IP Core Parameters - PLL Tab
Parameter | Legal Value | Description |
---|---|---|
Device Family | Intel® Stratix® 10 | Specifies the device family. |
Component | — | Specifies the targeted device. |
Speed Grade | — | Specifies the speed grade for targeted device. |
PLL Mode | Integer-N PLL | Specifies the mode used for the IOPLL IP core. The only legal selection is Integer-N PLL. |
Reference Clock Frequency | — | Specifies the input frequency for the input clock, refclk, in MHz. The default value is 100.0 MHz. The minimum and maximum value is dependent on the selected device. |
My reference clock frequency might change | Turn on or Turn off | Select this option if you expect the reference clock frequency to change at runtime. |
Enable Locked Output Port | Turn on or Turn off | Turn on to enable the locked port. |
Enable physical output clock parameters | Turn on or Turn off | Turn on to enter physical PLL counter parameters instead of specifying a desired output clock frequency. |
Operation Mode | direct, external feedback, normal, source synchronous, zero delay buffer, or lvds | Specifies the operation of the
PLL. The default operation is direct mode.
|
Compensated Outclk 5 | 0–8 | Allows you to select which output clock (outclk) to be compensated. The feedback mode compensates for the clock network delay of the outclk selected. This feedback mode ensures correct phase relationship between I/O PLL input and output clocks only for the selected outclk. |
Use Nondedicated Feedback Path 5 | Turn on or Turn off | Turn on to conserve clock resources and improve timing analysis. However, this feature creates frequency limitations and disables phase shift. |
Number of Clocks | 1–9 | Specifies the number of output clocks required for each device in the PLL design. The requested settings for output frequency, phase shift, and duty cycle are shown based on the number of clocks selected. |
Multiply Factor (M-Counter) 6 | 4–160 | Specifies the multiply factor of M-counter. |
Divide Factor (N-Counter) 6 | 1–110 | Specifies the divide factor of N-counter. |
Specify VCO Frequency | Turn on or Turn off | Allows you to restrict the VCO frequency to the specified value. This is useful when creating a PLL for LVDS external mode, or if a specific dynamic phase shift step size is desired. |
VCO Frequency 7 | — |
|
Give clock global name | Turn on or Turn off | Allows you to rename the output clock name. |
Clock Name | — | The user clock name for Synopsis Design Constraints (SDC). |
Divide Factor (C-Counter) 6 | 1-510 | Specifies the divide factor for the output clock (C-counter). |
Desired Frequency | — | Specifies the output clock frequency of the corresponding output clock port, outclk[], in MHz. The default value is 100.0 MHz. The minimum and maximum values depend on the device used. The PLL only reads the numerals in the first six decimal places. |
Actual Frequency | — | Allows you to select the actual output clock frequency from a list of achievable frequencies. The default value is the closest achievable frequency to the desired frequency. |
Phase Shift units | ps or degrees | Specifies the phase shift unit for the corresponding output clock port, outclk[], in picoseconds (ps) or degrees. |
Desired Phase Shift | — | Specifies the requested value for the phase shift. The default value is 0 ps. |
Actual Phase Shift | — | Allows you to select the actual phase shift from a list of achievable phase shift values. The default value is the closest achievable phase shift to the desired phase shift. |
Desired Duty Cycle | 0.0–100.0 | Specifies the requested value for the duty cycle. The default value is 50.0%. |
Actual Duty Cycle | — | Allows you to select the actual duty cycle from a list of achievable duty cycle values. The default value is the closest achievable duty cycle to the desired duty cycle. |
6.1.2. IOPLL IP Core Parameters - Settings Tab
Parameter | Legal Value | Description |
---|---|---|
PLL Bandwidth Preset | Low, Medium, or High | Specifies the PLL bandwidth preset setting. The default selection is Low. |
Lock Threshold Setting | Low Lock Time, Medium Lock Time, or High Lock Time |
This setting determines the sensitivity of the I/O PLL when detecting lock. This is a tradeoff between the time it takes to lock and the accuracy of the outclk frequency when locked is first asserted. For applications that require the I/O PLL to lock quickly, Low Lock Time is the best option. The estimated lock times are 30 µs + a × refclk_period, where a is 100, 2048, and 4095 for Low Lock Time, Medium Lock Time, and High Lock Time respectively. |
PLL Auto Reset | Turn on or Turn off | Automatically self-resets the PLL on loss of lock. |
Create a second input clk ‘refclk1’ | Turn on or Turn off | Turn on to provide a backup clock attached to your PLL that can switch with your original reference clock. |
Second Reference Clock Frequency 8 | — | Selects the frequency of the second input clock signal. The default value is 100.0 MHz. The minimum and maximum value is dependent on the device used. |
Create an ‘active_clk’ signal to indicate the input clock in use 8 | Turn on or Turn off | Turn on to create the activeclk output. The activeclk output indicates the input clock which is in use by the PLL. Output signal low indicates refclk and output signal high indicates refclk1. |
Create a ‘clkbad’ signal for each of the input clocks 8 | Turn on or Turn off | Turn on to create two clkbad outputs, one for each input clock. Output signal low indicates the clock is working and output signal high indicates the clock is not working. |
Switchover Mode 8 | Automatic Switchover, Manual Switchover, or Automatic Switchover with Manual Override | Specifies the switchover mode for
design application. The IP supports three switchover modes:
|
Switchover Delay 8 | 0–7 | Adds a specific amount of cycle delay to the switchover process. |
Access to PLL LVDS_CLK/LOADEN output port | Disabled, Enable LVDS_CLK/LOADEN 0, or Enable LVDS_CLK/LOADEN 0 & 1 | Select Enable
LVDS_CLK/LOADEN 0 or Enable LVDS_CLK/LOADEN o & 1 to enable the PLL
lvds_clk or loaden output port. Enables this parameter in case the PLL feeds an LVDS SERDES block with external PLL. When using the I/O PLL outclk ports with LVDS ports, outclk[0..3] are used for lvds_clk[0,1] and loaden[0,1] ports, outclk4 can be used for coreclk ports. |
Enable access to the PLL DPA output port | Turn on or Turn off | Turn on to enable the PLL DPA output port. |
Enable access to PLL external clock output port | Turn on or Turn off | Turn on to enable the PLL external clock output port. |
Specifies which outclk to be used as extclk_out[0] source | C0 – C8 | Specifies the outclk port to be used as extclk_out[0] source. |
Specifies which outclk to be used as extclk_out[1] source | C0 – C8 | Specifies the outclk port to be used as extclk_out[1] source. |
6.1.3. IOPLL IP Core Parameters - Cascading Tab
Parameter | Legal Value | Description |
---|---|---|
Create a ‘cascade out’ signal to connect with a downstream PLL | Turn on or Turn off | Turn on to create the cascade_out port, which indicates that this PLL is a source and connects with a destination (downstream) PLL. |
Specifies which outclk to be used as cascading source | 0-8 | Specifies the cascading source. |
Create an adjpllin or cclk signal to connect with an upstream PLL | Turn on or Turn off | Turn on to create an input port, which indicates that this PLL is a destination and connects with a source (upstream) PLL. |
Create a permit_cal signal to connect with an upstream PLL | Turn on or Turn off | Turn on to create an input port to enable destination (downstream) PLL power-up calibration. Connect source (upstream) PLL locked signal to this input port. |
6.1.4. IOPLL IP Core Parameters - Dynamic Reconfiguration Tab
Parameter | Legal Value | Description |
---|---|---|
Enable dynamic reconfiguration of PLL | Turn on or Turn off | Turn on to enable the dynamic reconfiguration of this PLL (in conjunction with the IOPLL Reconfig Intel® FPGA IP core). |
Enable access to dynamic phase shift ports | Turn on or Turn off | Turn on to enable the dynamic phase shift interface with the PLL. |
MIF Generation Option 9 | Generate New MIF File, Add Configuration to Existing MIF File, or Create MIF File during IP Generation |
Either create a new .mif file containing the current configuration of the I/O PLL by clicking Create MIF File or add this configuration to an existing .mif file by clicking Append to MIF File. A .mif file also can be opted to be generated during IP generation. The generated .mif file contains current PLL profile and a collection of physical parameters—such as M, N, C, K, bandwidth, and charge pump—that defines that PLL. You can use this .mif file during dynamic reconfiguration to reconfigure the I/O PLL to its current settings. |
Path to New/Existing MIF file 9 | — | Enter location and file name of the new .mif file to be created or existing .mif file to be appended. |
Name of Current Configuration 9 | — |
Enter the file name of the existing .mif file you intend to add to. |
6.1.5. IOPLL IP Core Parameters - Advanced Parameters Tab
Parameter | Legal Value | Description |
---|---|---|
Advanced Parameters | — | Displays a table of physical PLL settings that are implemented based on your input. |
6.2. IOPLL IP Core Ports and Signals
Port Name | Type | Condition | Description |
---|---|---|---|
refclk | Input | Required | The reference clock source that drives the I/O PLL. |
rst | Input | Required | The asynchronous reset port for the output clocks. Drive this port high to reset all output clocks to the value of 0. |
fbclk | Input | Optional |
The external feedback input port for the I/O PLL. The IOPLL IP core creates this port when the I/O PLL is operating in external feedback mode or zero-delay buffer mode. To complete the feedback loop, a board-level connection must connect the fbclk port and the external clock output port of the I/O PLL. |
fboutclk | Output | Optional |
The port that feeds the fbclk port through the mimic circuitry. The fboutclk port is available only if the I/O PLL is in external feedback mode. |
zdbfbclk | Bidirectional | Optional |
The bidirectional port that connects to the mimic circuitry. This port must connect to a bidirectional pin that is placed on the positive feedback dedicated output pin of the I/O PLL. The zdbfbclk port is available only if the I/O PLL is in zero-delay buffer mode. |
locked | Output | Optional | The IOPLL IP core drives this port high when the PLL acquires lock. The port remains high as long as the I/O PLL is locked. The I/O PLL asserts the locked port when the phases and frequencies of the reference clock and feedback clock are the same or within the lock circuit tolerance. When the difference between the two clock signals exceeds the lock circuit tolerance, the I/O PLL loses lock. |
refclk1 | Input | Optional | Second reference clock source that drives the I/O PLL for clock switchover feature. |
extswitch | Input | Optional | Active low signal. Assert the extswitch signal low (1’b0) for at least three clock cycles to manually switch the clock. |
activeclk | Output | Optional | Output signal to indicate which reference clock source is in used by I/O PLL. |
clkbad | Output | Optional | Output signal that indicates the status of reference clock source is good or bad. |
cascade_out | Output | Optional | Output signal that feeds into downstream I/O PLL. |
adjpllin | Input | Optional | Input signal that feeds from upstream I/O PLL. |
outclk_[] | Output | Optional | Output clock from I/O PLL. |
permit_cal | Input | Optional | This is an input port for the downstream I/O PLL. Connect this permit_cal port to the locked output port of the upstream I/O PLL. Connecting this permit_cal port ensures that the cascaded I/O PLLs are calibrated in the correct order. |
6.3. Dynamic Phase Shift Ports in the IOPLL IP Core
Port | Direction | Description | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
scanclk | Input | Dynamic phase shift clock that drives the IOPLL IP core dynamic phase shift operation. This port must be connected to a valid clock source. The maximum input clock frequency is 100 MHz. | ||||||||||||||||||||||
phase_en | Input | Active high signal. Asserts to start the dynamic phase shift operation. phase_en can only be asserted 4 clocks after phase_done assertion. | ||||||||||||||||||||||
updn | Input | Determines the direction of dynamic phase shift. When updn = 0, phase shift is in negative direction. When updn = 1, phase shift is in positive direction. | ||||||||||||||||||||||
cntsel[4..0] | Input |
Determines the counter to be selected to perform
dynamic phase shift operation.
|
||||||||||||||||||||||
num_phase_shift[2..0] | Input | Determines the number of phase shifts per dynamic phase shift operation. Up to seven phase shifts per operation are possible. Each phase shift step is equal to 1/8 of I/O PLL VCO period. num_phase_shift must never be set to 0 in DPS mode. | ||||||||||||||||||||||
phase_done | Output | The IOPLL IP core drives this port high for one scanclk cycle after dynamic phase shift operation is complete. |
7. IOPLL Reconfig Intel FPGA IP Core References
7.1. Avalon -MM Interface Ports in the IOPLL Reconfig IP Core
Port | Direction | Description |
---|---|---|
mgmt_clk | Input | Dynamic reconfiguration clock that drives the IOPLL Reconfig IP core. The maximum input clock frequency is 100 MHz. This clock can be an independent clock source. It must be free running, which means it cannot be connected to the output of the I/O PLL being reconfigured. |
mgmt_reset | Input | Active high signal. Synchronous reset input to clear all the data in the IOPLL Reconfig IP core. |
mgmt_waitrequest | Output | This port goes high when PLL reconfiguration process started and remains high during PLL reconfiguration. After PLL reconfiguration process completed, this port goes low. |
mgmt_write | Input | Active high signal. Asserts to indicate a write operation. |
mgmt_read | Input | Active high signal. Asserts to indicate a read operation. |
mgmt_writedata[7..0] | Input | Writes data to this port when mgmt_write signal is asserted. |
mgmt_readdata[7..0] | Output | Reads data from this port when mgmt_read signal is asserted. |
mgmt_address[9..0] | Input | Specifies the address of the data bus for a read or write operation. |
reconfig_from_pll[10..0] | Input | Bus that connects to reconfig_from_pll[10..0] bus in the IOPLL Intel® FPGA IP core. |
reconfig_to_pll[29..0] | Output | Bus that connects to reconfig_to_pll[29..0] bus in the IOPLL IP core. |
7.2. Address Bus and Data Bus Settings
Assign a value of “0” for all the unused bits in the address bus and the data bus during reconfiguration operations.
7.2.1. Address Bus and Data Bus Settings for Advanced Mode Reconfiguration
Register Name | Address (Binary) | Counter Bit Setting | |
---|---|---|---|
M Counter | High Count | 00000100 |
|
Low Count | 00000111 | ||
Bypass Enable 10 | 00000101 |
|
|
Odd Division 10 | 00000110 |
|
|
N Counter | High Count | 00000000 |
|
Low Count | 00000010 | ||
Bypass Enable 10 | 00000001 |
|
|
Odd Division 10 | 00000001 |
|
|
C0 Counter | High Count | 00011011 |
|
Low Count | 00011110 | ||
Bypass Enable 10 | 00011100 |
|
|
Odd Division 10 | 00011101 |
|
|
C1 Counter | High Count | 00011111 |
|
Low Count | 00100010 | ||
Bypass Enable 10 | 00100000 |
|
|
Odd Division 10 | 00100001 |
|
|
C2 Counter | High Count | 00100011 |
|
Low Count | 00100110 | ||
Bypass Enable 10 | 00100100 |
|
|
Odd Division 10 | 00100101 |
|
|
C3 Counter | High Count | 00100111 |
|
Low Count | 00101010 | ||
Bypass Enable 10 | 00101000 |
|
|
Odd Division 10 | 00101001 |
|
|
C4 Counter | High Count | 00101011 |
|
Low Count | 00101110 | ||
Bypass Enable 10 | 00101100 |
|
|
Odd Division 10 | 00101101 |
|
|
C5 Counter | High Count | 00101111 |
|
Low Count | 00110010 | ||
Bypass Enable 10 | 00110000 |
|
|
Odd Division 10 | 00110001 |
|
|
C6 Counter | High Count | 00110011 |
|
Low Count | 00110110 | ||
Bypass Enable 10 | 00110100 |
|
|
Odd Division 10 | 00110101 |
|
|
C7 Counter | High Count | 00110111 |
|
Low Count | 00111010 | ||
Bypass Enable 10 | 00111000 |
|
|
Odd Division 10 | 00111001 |
|
|
C8 Counter | High Count | 00111011 |
|
Low Count | 00111110 | ||
Bypass Enable 10 | 00111100 |
|
|
Odd Division 10 | 00111101 |
|
|
Charge Pump Current 10 | Charge pump setting [2:0] | 00000001 |
|
Charge pump setting [5:3] | 00001101 |
|
|
Bandwidth Setting 10 | — | 00001010 |
|
Ripplecap Setting 10 | — | 00001010 |
|
Calibration 10 | Calibration Request | 01001001 |
|
Calibration Enable | 01001010 |
|
7.2.1.1. Data Bus Setting for Bandwidth Control and Charge Pump
Multiply Factor 11 | Low Bandwidth | ||
---|---|---|---|
Bandwidth Control Setting Data [6:3] |
Charge Pump Setting [2:0] Address = 00000001 Data [6:4] |
Charge Pump Setting [5:3] Address = 00001101 Data [7:5] |
|
4–5 | 4'b0011 | 3'b011 | 3'b000 |
6–15 | 4'b0011 | 3'b100 | 3'b000 |
16–23 | 4'b0011 | 3'b100 | 3'b000 |
24–43 | 4'b0100 | 3'b100 | 3'b000 |
44–64 | 4'b0101 | 3'b100 | 3'b000 |
65–124 | 4'b0110 | 3'b100 | 3'b000 |
>124 | 4'b0110 | 3'b110 | 3'b000 |
Multiply Factor 11 | Medium Bandwidth | ||
---|---|---|---|
Bandwidth Control Setting Data [6:3] |
Charge Pump Setting [2:0] Address = 00000001 Data [6:4] |
Charge Pump Setting [5:3] Address = 00001101 Data [7:5] |
|
4–5 | 4'b0011 | 3'b100 | 3'b000 |
6–15 | 4'b0011 | 3'b111 | 3'b000 |
16–23 | 4'b0011 | 3'b000 | 3'001 |
24–43 | 4'b0100 | 3'b000 | 3'001 |
44–64 | 4'b0101 | 3'b000 | 3'001 |
65–124 | 4'b0101 | 3'b000 | 3'001 |
>124 | 4'b0110 | 3'b000 | 3'001 |
Multiply Factor 11 | High Bandwidth | ||
---|---|---|---|
Bandwidth Control Setting Data [6:3] |
Charge Pump Setting [2:0] Address = 00000001 Data [6:4] |
Charge Pump Setting [5:3] Address = 00001101 Data [7:5] |
|
4–5 | 4'b0011 | 3'b101 | 3'b000 |
6–15 | 4'b0011 | 3'b010 | 3'b001 |
16–23 | 4'b0011 | 3'b100 | 3'b001 |
24–43 | 4'b0100 | 3'b100 | 3'b001 |
44–64 | 4'b0100 | 3'b100 | 3'b001 |
65–124 | 4'b0101 | 3'b100 | 3'b001 |
>124 | 4'b0101 | 3'b100 | 3'b001 |
7.2.1.2. Data Bus Setting for Ripplecap
Multiply Factor 12 | Ripplecap Setting Address = 00001010 Data [2:1] |
---|---|
4-5 | 2'b00 |
6-15 | 2'b00 |
16-23 | 2'b10 |
24-43 | 2'b00 |
44-64 | 2'b10 |
65-124 | 2'b10 |
>124 | 2'b10 |
7.2.2. Output Clock and the Corresponding Data Bit Setting for Clock Gating Reconfiguration
Output Clock | Data Bus Bit Setting (Binary) | |
---|---|---|
C0 | data[0] |
Gated = 1'b0 Ungated = 1'b1 |
C1 | data[1] | |
C2 | data[2] | |
C3 | data[3] | |
C4 | data[4] | |
C5 | data[5] | |
C6 | data[6] | |
C7 | data[7] |
7.2.3. Data Bus Setting for Dynamic Phase Shift for IOPLL Reconfig IP Core
Write Data Bus Setting | Description | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
data[2:0] | Determines the number of phase shifts per dynamic phase shift operation. Up to seven phase shifts per operation are possible. Each phase shift step is equal to 1/8 of I/O PLL VCO period. | ||||||||||||||||||||||
data[3] | Determines the direction of dynamic phase shift. When data[3] = 0, phase shift is in negative direction. When data[3] = 1, phase shift is in positive direction. | ||||||||||||||||||||||
data[7:4] |
Determines the counter to be selected to perform dynamic phase
shift operation.
|
8. Intel Stratix 10 Clocking and PLL User Guide Archives
Intel® Quartus® Prime Version | User Guide |
---|---|
19.3 | Intel Stratix 10 Clocking and PLL User Guide |
19.2 | Intel Stratix 10 Clocking and PLL User Guide |
18.1 | Intel Stratix 10 Clocking and PLL User Guide |
18.0 | Intel Stratix 10 Clocking and PLL User Guide |
17.1 | Intel Stratix 10 Clocking and PLL User Guide |
9. Document Revision History for the Intel Stratix 10 Clocking and PLL User Guide
Document Version | Intel® Quartus® Prime Version | Changes |
---|---|---|
2020.09.28 | 20.3 | Added the IP-XACT File Generation section under IOPLL Intel® FPGA IP Core. |
2020.03.06 | 19.3 | Added description about the bidirectional I/O pin must not be globally promoted in the Zero-Delay Buffer Mode section. |
2019.12.10 | 19.3 | Added a guideline for design with encrypted IOPLL Intel® FPGA IP core in the IP Core Constraints section. |
2019.10.17 | 19.3 |
|
2019.07.01 | 19.2 |
|
2018.12.24 | 18.1 |
|
2018.08.03 | 18.0 | Added diagrams on PLL cascading connectivity in the PLL Cascading section. |
2018.05.07 | 18.0 |
|
Date | Version | Changes |
---|---|---|
December 2017 | 2017.12.07 |
|
May 2017 | 2017.05.26 |
|
October 2016 | 2016.10.31 | Initial release. |