ALTERA DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THIS PATCH 
WILL MEET YOUR REQUIREMENTS, OR THAT THE OPERATION OF THIS PATCH 
WILL BE UNINTERRUPTED OR ERROR-FREE. 

//**************************************************************** 
readme_patch_9.1_1.38.txt 
Readme file for Quartus II 9.1 Patch 1.38 (Linux version) 
Copyright (C) Altera Corporation 2010 All right reserved. 
Patch created on March 01 2010
Patch SPR#: 334693 
SPRs fixed: 334152, 328038, 330912
//**************************************************************** 

Problem:  Configuration failure occurs when a customer program the 
          EPCS64 with compressed .pof/.rpd/.jic file generated in 
          QII v9.1 SP1.


Solution:  Added additional postamble byte to bitstream for the 
           following conditions:
           
                -Configuration mode is ACTIVE_SERIAL
                -Compression is enabled
                
           Device family is Stratix II, Stratix II GX, Arria GX, 
           Cylcone & Cyclone II


Caution - You must either have previously installed the Quartus II 
          software version 9.1 SP1 or must install the Quartus II 
          software version 9.1 SP1 before installing this patch. 
          Otherwise, the patch will not be installed correctly and 
          the Quartus II software will not run properly. 