The errors are listed in numerical order and appear in this format:

   TokenExp ISA 0 042E:  Adapter initialize failed
   ____________ _ _____  _________________________
    |           |   |                 |
    |           |   |                 |
    |           |   |                 |- message
    |           |   |
    |           |   |- message number (see entries below)
    |           |
    |           |- *0 = only Token Ring adapter in this computer
    |               1 = second Token Ring adapter in this computer
    |               2 = third Token Ring adapter in this computer
    |               3 = fourth Token Ring adapter in this computer
    |
    |              *Order number specified in device driver line
    |
    |- adapter identification

Error 033E

Message:Bring-up diagnostics failed, ireg=0xNNNN, ct=0xNNNN

Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 034E

Message:Init setup failed, ireg=0xNNNN, ct=0xNNNN

Action: See suggested action for Error 033E.

Error 035E

Message:Open failed.

Action: Make sure the adapter's interrupt level setting doesn't conflict with any other adapter in this computer.

Error 036

Message:Close failed.

Action: Make sure the cable is securely connected and in good condition (no damage, no bent pins, etc.)

Error 037

Message:Command execution timeout

Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 039

Message:Adapter RAM test failure addr=0xNNNN.

Action: Some of the adapter's RAM may not be functioning. Contact your local dealer or Intel Technical support.

Error 042

Message:Adapter Initialize Failed.

Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 043

Message:Adapter reset timeout.

Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 051

Message:Open command retrying. Open rejected cmd=0x0003, status=0x02yz stat=0x02yz', where y indicates the Open Phase in which the error was detected and z indicates the error type.

y Open Phase z Error Type
1 Lobe media test 1 Function Failure
2 Physical Insertion 2 Signal Loss
3 Address Verification 5 Timeout
4 Participation in ring poll 6 Ring Failure
5 Request initialization 7 Ring beaconing
8 Duplicate Node Address
9 Request Initialization
A Remove received

Action:

  • Make sure the cable is securely connected and in good condition (no damage, no bent pins, etc.)
  • Check that the adapter's ring speed (4Mbit/16Mbit) is the same as the ring speed of the Token-Ring network on which it is inserted.

Error 052

Message:Close rejected cmd=0x0002, status=0xZZZZ.

Action: See suggested action for Error 051.

Error 066

Message:Download of software to adapter failed.

Action: Rerun the diagnostics. If the error continues, contact your dealer or Intel Technical Support.

Error 071E

Message:Initialize failed, SCB<<<>>0000C1E2D48B

Action: Make sure the adapter's interrupt and DMA options are set correctly, then rerun the diagnostics.

Error 072E

Message:Initialize failed, SSB<<<>>FFFFD1D7C5D9C3D4

Action: Make sure the adapter's interrupt and DMA options are set correctly, then rerun the diagnostics.

Error 073

Message:Open command rejected - max retry count reached.

Action: See suggested action for Error 051.

Error 080

Message:Receive failed.

Action:

  • Make sure the cable is securely connected and in good condition (no damage, no bent pins, etc.)
  • Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 082

Message:Transmit failed.

Action: See suggested action for error 080.

Error 084

Message:Timeout error (rx/tx).

Action: See suggested action for error 080.

Error 086

Message:Data compare error on received data.

Action: See suggested action for error 080.

Error 088

Message:Bring-up diagnostic failed - timeout.

Action: Check the adapter configuration and make sure that it does not conflict with other installed devices.

Error 089

Message:Adapter RAM or DMA test failure - error code: XXXX

Action: The adapter may be defective. Contact your local dealer or Intel Technical support.