Diagnostic Failure Error Messages

The errors are listed in numerical order and appear in this format:

     Intel xxxx   0  042E:        Adapter initialize failed

     ¦                   ¦         ¦          ¦
     ¦                   ¦         ¦          - message
     ¦                   ¦         ¦
     ¦                   ¦         ¦- message number (see entries below)
     ¦                   ¦
     ¦                   --  0 = only Token Ring adapter in this computer
     ¦                   1 = second Token Ring adapter in this computer
     ¦                   2 = third Token Ring adapter in this computer
     ¦                   3 = fourth Token Ring adapter in this computer
     ¦                   Order number specified in device driver line
     ¦
     - adapter identification

Error 033E

Message: Bring-up diagnostics failed, ireg=0xNNNN, ct=0xNNNN
Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 034E

Message: Init setup failed, ireg=0xNNNN, ct=0xNNNN
Action: See suggested action for Error 033E.

Error 035E

Message: Open failed.
Action: Make sure the adapter's interrupt level setting doesn't conflict with any other adapter in this computer.

Error 036

Message: Close failed.
Action: Make sure the cable is securely connected and in good condition (no damage, no bent pins, etc.)

Error 037

Message: Command execution timeout
Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 039

Message: Adapter RAM test failure addr=0xNNNN.
Action: Some of the adapter's RAM may not be functioning. Contact your local dealer or Intel Technical support.

Error 042

Message: Adapter Initialize Failed.
Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 043

Message: Adapter reset timeout.
Action: Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 051

Message: Open command retrying. Open rejected cmd=0x0003, status=0x02yz', where y indicates the Open Phase in which the error was detected and z indicates the error type.

    y Open Phase

    1 Lobe media test
    2 Physical Insertion
    3 Address Verification
    4 Participation in ring poll
    5 Request initialization

    z Error Type

    1 Function Failure
    2 Signal Loss
    5 Timeout
    6 Ring Failure
    7 Ring beaconing
    8 Duplicate Node Address
    9 Request Initialization
    A Remove received

Action: Make sure the cable is securely connected and in good condition (no damage, no bent pins, etc.)Make sure the adapter's ring speed (4Mbit/16Mbit) is the same as the ring speed of the Token-Ring network on which it is inserted.

Error 052

Message: Close rejected cmd=0x0002, status=0xZZZZ.
Action: See suggested action for Error 051.

Error 066

Message: Download of software to adapter failed.
Action: Rerun the diagnostics. If the error continues, contact your dealer or Intel Technical Support.

Error 071E

Message: Initialize failed, SCB<<>>0000C1E2D48B
Action: Make sure the adapter's interrupt and DMA options are set correctly, then rerun the diagnostics.

Error 072E

Message: Initialize failed, SSB<<>>FFFFD1D7C5D9C3D4
Action: Make sure the adapter's interrupt and DMA options are set correctly, then rerun the diagnostics.

Error 073

Message: Open command rejected - max retry count reached.
Action: See suggested action for Error 051.

Error 080

Message: Receive failed.
Action: Make sure the cable is securely connected and in good condition (no damage, no bent pins, etc.)Make sure the adapter's option settings are correct and don't conflict with any other device in this computer.

Error 082

Message: Transmit failed.
Action: See suggested action for error 080.

Error 084

Message: Timeout error (rx/tx).
Action: See suggested action for error 080.

Error 086

Message: Data compare error on received data.
Action: See suggested action for error 080.

Error 088

Message: Bring-up diagnostic failed - timeout.
Action: Check the adapter configuration and make sure it does not conflict with other installed devices.

Error 089

Message: Adapter RAM or DMA test failure - error code: XXXX
Action: The adapter may be defective. Contact your local dealer or Intel Technical support

This applies to:
TokenExpress™ 16/p Adapter
TokenExpress™ EISA 16/4 Adapter
TokenExpress™ EISA 32 Adapter
TokenExpress™ MCA Adapter



Solution ID: CS-012016
Date Created: 31-May-2004
Last Modified: 23-Oct-2006