v3.03
Location of Driver: \NDIS\EPRO.DOS (for LANSUP with Extended NIF)
Location of Driver: \DOS\EPROODI.COM (for ODINSUP)
General instructions
There are two methods to connect the EtherExpress PRO/10 LAN adapter
simultaneously to an IBM AS/400* (or other Host based on DLC protocol)
and Novell* server:
Using LANSUP (NDIS based), or
Using ODINSUP (ODI based).
LANSUP.COM and ODINSUP.COM are Novell* drivers and are included in the
VLMUPx.EXE (where x is the number of the latest offering) file available
on Compuserve* in the Novell NetWire* forum.
The first set of example files are using the LANSUP driver.
Sample CONFIG.SYS file for LANSUP
DEVICE = \LANMAN\PROTMAN.DOS (version 1.1 or later )
DEVICE = \LANMAN\EPRO.DOS
DEVICE = \LANMAN\DXMA0MOD.SYS (version 1.35 or later)
DEVICE = \LANMAN\DXME0MOD.SYS (version 1.35 or later)
DEVICE = C:\PCS\EIMPCS.SYS
DEVICE = C:\PCS\ECYDDX.SYS
Sample AUTOEXEC.BAT file for LANSUP
CD\LANMAN
NETBIND (version 1.1 or later )
LSL (version 2.12 or later)
LANSUP (version 1.27 or later)
IPXODI (version 3.00 or later)
NETX or VLM (version 3.32 of NETX.EXE or later version 1.20 of VLM.EXE or later)
F:
LOGIN
C:\PCS\STARTPCS
NOTE: It's normal for LANSUP to report
"Board 1, Frame TOKEN-RING, LSB Mode" when loading.
Sample PROTOCOL.INI file for LANSUP
[PROTOCOL MANAGER]
DRIVERNAME = PROTMAN$
[ETHERNET]
DRIVERNAME = DXME0$
BINDINGS = EPRO
[EPRO]
DRIVERNAME = EPRO$
Sample NET.CFG file for LANSUP
Link Driver LANSUP
Max Frame Size = 1490
NetWare DOS Requester
First Network Drive = F
The second set of example files (following) are using the ODINSUP (ODI
based) driver.
Sample CONFIG.SYS file for ODINSUP
DEVICE = \LANMAN\PROTMAN.DOS /I:C:\LANMAN (version 1.1 or later)
DEVICE = \LANMAN\DXMA0MOD.SYS (version 1.35 or later)
DEVICE = \LANMAN\DXME0MOD.SYS (version 1.35 or later)
DEVICE = C:\PCS\EIMPCS.SYS
DEVICE = C:\PCS\ECYDDX.SYS
Sample AUTOEXEC.BAT file for ODINSUP
CD\LANMAN
LSL (version 2.12 or later)
EPROODI
ODINSUP (version 2.00 or later)
NETBIND (version 1.1 or later)
IPXODI (version 3.00 or later)
NETX or VLM (version 3.32 of NETX.EXE
or later version 1.20 of
VLM.EXE or later)
F:
LOGIN
C:\PCS\STARTPCS
Sample PROTOCOL.INI file for ODINSUP
[PROTOCOL MANAGER]
DRIVERNAME = PROTMAN$
[ETHERNET]
DRIVERNAME = DXME0$
BINDINGS = EPROODI
[EPROODI]
DRIVERNAME = EPROODI$
IOADDRESS = 0x300
Sample NET.CFG (C:\LANMAN\NET.CFG) file for ODINSUP
Link Driver EPROODI
Frame ethernet_802.2
Frame ethernet_II
Frame ethernet_802.3
Frame ethernet_snap
Protocol ODINSUP
Bind EPROODI
NetWare DOS Requester
First Network Drive = F
This applies to:
|