Server Products
Intel® Entry Storage System SS4200-E
Obtaining System Diagnostic Files for Issue Investigation and Troubleshooting

Major steps to gather a system diagnostic file for issue investigation and troubleshooting:

  1. Open the Intel® Entry Storage System manager and log in if necessary
  2. Navigate to the support.html web address
  3. Open the Dump Files applet
  4. Create a diagnostic dump file
  5. Download and save to the local computer
  6. View diagnostic dump using a web browser
  7. Helpful diagnostic location descriptions

Detailed steps to gather a system diagnostic file for issue investigating and troubleshooting:

  1. Open the Intel® Entry Storage System manager and log in if necessary:

    back to top back to top

  2. Select the “Settings” tab and replace settings.html?t….. in the browser address bar with support.html:

    back to top back to top

  3. When the support configuration page appears select “Dump Files”:

    back to top back to top

  4. Select “Dump” to create a new dump file with the most recent information. Diagnostic dump files are created on demand by pressing the “Dump” button:

    1. System state information is gathered from the storage system. This can take up to a minute or two with no indication except for the “Gathering system state” indicator:

    back to top back to top

  5. The new Dump file appears. Double-click the new Dump file and save to the local hard disk:

    The dump file is saved as a tar.gz compressed file. Decompress to make the diagnostic dump file folder available for viewing.

    back to top back to top

  6. Open the diagnostic dump file folder:


    The resulting Dump files can be viewed through a web browser. Double-click the parent directory index.html file to view the subfolder information.

    1. The Dump file folders are available as hyperlinks:

      Files within these folders are also hyperlinks and can be viewed within the browser. You may be required to specify the application to open specific file types (.log, .conf, .d...). These are Linux based file types. For the most part, WordPad* is generally recommended to maintain readable formatting.

    back to top back to top

  7. Helpful locations to check for issue troubleshooting:

    config/etc

    sohoFlash.xml - Contains current firmware, storage system name and time zone information.

    disks

    sdx.info – Disk “x” information. Disks are designated as a, b, c, or d

    Installed USB drives will appear here as sd?.info and so on following HDDs

    ip

    ifconfig.out – System network adapter configuration. ifconfig command output

    log

    messages – System messages log file in chronological event order

    soho.log – Log file for general storage device events

    sohoaudit.log - Log file for storage device audit events

    mounts

    index.html - Mount point information from Linux df and mount commands

    procs

    top.out - List of processes using largest amount system CPU time or memory at time the dump file was created

    raid

    md0.out - RAID Information from mdadm and mdstat command

    usb

    index.html - Detailed information on USB devices. For additional USB Disk information see the "disks"output

back to top back to top

This applies to:

Intel® Entry Storage System SS4200-E



Solution ID: CS-031424
Last Modified: 21-Oct-2014
Date Created: 22-Feb-2010
Back to Top