Intel® Entry Storage System SS4200-E Front Panel LEDs
| A |
USB Port 0 |
F |
NIC Activity LED |
| B |
Disk Drive Activity LED |
G |
Disk Drive 1 Status LED |
| C |
Disk Drive 2 Status LED |
H |
Power/Status LED Push Button |
| D |
Disk Drive 3 Status LED |
I |
Disk Drive 4 Status LED |
| E |
USB Port 1 |
| |
Front Panel LEDs State definitions:
| LED |
Color |
Definition |
| Power/Status Pushbutton LED |
Constant blue |
Power present. System is booted and operational |
| Flashing blue |
System is in process of booting up |
| Amber |
A critical or non-recoverable condition has occurred |
| Off |
System is off. No power present |
| NIC Link
Note: Rear Ethernet port provides standard link and port activity LEDs |
Constant blue |
Indicates an active Ethernet connection |
| Off |
No active Ethernet connection |
| Global Disk Drive Activity LED |
Constant blue |
Activity is present on any disk drive |
| Disk Drive Status |
Constant blue |
Indicates the drive is available |
| Constant amber |
Indicates a drive fault has occurred |
| Flashing amber/blue |
Indicates the drive is rebuilding |
| Off |
Disk drive is not ready or not present | |
Critical or non-recoverable status condition triggers causing an amber status LED are RAID or disk failure, thermal, fan and voltage conditions.
Thermal sensors:
§ Internal CPU thermal sensor
§ Thermal sensor on the baseboard near the center of the board
Fan speeds
§ The power supply fan is not monitored
Power Supply voltages
This applies to:
|