Server Products
Intel® RAID Controller SRCS14L
Jumper Setting

The Intel® RAID Controller SRCS14L normally comes ready to be installed into the computer serverboard immediately. However, jumper settings (see figure below) are available to:

  • Reprogram the RAID firmware that is located in the flash memory of the IIR controller.
  • Set the PCI bus speed (force 33 MHz or auto-negotiate 33/66 MHz).
Controller Jumper Settings
Jumper Block Jumper Position Definition
J1 Jumper on pins [1-2] IOP is in reset mode with firmware recovery enabled.
Jumper on pins [2-3] IOP is in normal run mode.
No jumpers IOP is in normal run mode.
J4 Jumper on pins [1-2] PCI bus is forced to 33 MHz.
Jumper on pins [2-3] PCI bus auto-negotiates 33 MHz or 66 MHz.
No jumpers PCI bus auto-negotiates 33 MHz or 66 MHz.

J1 - IOP mode select jumper block: This jumper is used to place the IOP in reset, which enables the flash chip to be programmed to recover resident firmware (FW).

J4 - PCI bus speed: Leave this jumper in the default position (pins 2-3 to auto-negotiate 33/66 Mhz) unless instructed to do otherwise by customer support or a specification update.