Which PCI Slot can the Zero Channel RAID Card be Installed in?

The Intel® Server Board SE7501BR2 is capable of supporting zero channel RAID add-in cards. The ZCR cards are only supported in PCI-X Slot 4 (see figure below) located in the P64-B segment.

The ZCR add-in cards leverage the on-board SCSI controller along with their own built-in intelligence to provide a complete RAID controller subsystem on-board. The baseboard uses an implementation commonly referred to as RAID I/O Steering (RAIDIOS) specification version 1.0 to support this feature.

When one of the supported RAID cards is installed, the SCSI interrupts are routed to the RAID adapter instead of to the PCI interrupt controller. In addition, the IDSEL of the SCSI controller is not driven to the controller and thus will not respond as an on board device. The host-based I/O device is effectively hidden from the system.

For a list of supported Zero Channel RAID cards, please refer to the tested hardware and operating system list.

This applies to:
Intel® Server Board SE7501BR2



Solution ID: CS-007208
Date Created: 30-Nov-2003
Last Modified: 03-Nov-2005