Server Products
Server Products
TA-1052 - Damaged RMFBU Can Cause RAID Controller to Remain in Write Back Mode

Technical Advisory (PDF) icon
When a RAID Maintenance Free Backup Unit (RMFBU) has damaged electrical components, a RAID controller and attached RMFBU can remain in write back mode. This document describes the issue, root cause, and corrective action.

Filename: TA-1052-1.pdf
Size: 29.1 KB
Date: March 2014


Note: PDF Files require Adobe Acrobat* Reader*

This applies to:

Intel® Integrated RAID Module RMS25CB040
Intel® Integrated RAID Module RMS25CB080
Intel® Integrated RAID Module RMS25PB040
Intel® Integrated RAID Module RMS25PB080
Intel® Integrated RAID Module RMS3CC040
Intel® Integrated RAID Module RMS3CC080
Intel® Integrated RAID Module RMT3CB080
Intel® Integrated RAID Module RMT3PB080
Intel® RAID Controller RS25AB080
Intel® RAID Controller RS25SB008
Intel® RAID Controller RS3DC040
Intel® RAID Controller RS3DC080
Intel® RAID SSD Cache Controller RCS25ZB040
Intel® RAID SSD Cache Controller RCS25ZB040LX

Solution ID: CS-034703
Last Modified: 18-Nov-2014
Date Created: 11-Mar-2014