Cluster nodes may lose access to the shared drives

In Microsoft* Windows Enterprise Server 2008 Cluster failover testing, it has been observed that cluster nodes may lose access to the clustered shared LUN drives, if a compute module is power cycled.

Resetting the first Storage Control Module (SCM), regardless of drive affinity; or power cycling the entire chassis will restore service.

This issue was fixed in the 2.7 firmware release.

Operating System:
Windows Server 2008*

This applies to:
Intel® Compute Module MFS5000SI
Intel® Modular Server System MFSYS25
Intel® Modular Server System MFSYS35

Solution ID: CS-030103