Search
Support & Downloads
Server Products
Intel® RAID Controllers
Drive Removal and Immediate Re-insertion May Cause An Array Failure [PDF]

A RAID 1, 4, 5, or 10 array configured using one of the Intel® RAID controllers listed in the TA_617 may experience a non-recoverable drive failure when the cache on the drives is turned on and one of the drives is removed and immediately reinserted. Please refer to the below technical advisory [TA_617.PDF] for more details.

PDF Technical Advisory [PDF]
File Name: TA_617.PDF
Size: 91361 bytes
Date: 1/27/2003 10:18:09 PM

Note: PDF Files require Adobe Acrobat* Reader



   This link will take you off of the Intel Web site. Intel does not control the content of the destination Web Site.

This applies to:
Intel® RAID Controller SRCMR
Intel® RAID Controller SRCS14L
Intel® RAID Controller SRCU32
Intel® RAID Controller SRCU42L
Intel® RAID Controller SRCZCR
Intel® Server RAID Controller SRCU21
Intel® Server RAID Controller SRCU31
Intel® Server RAID Controller SRCU31A
Intel® Server RAID Controller SRCU31L
Intel® Server RAID Controller SRCU31LA



Solution ID: CS-010799
Date Created: 03-May-2004
Last Modified: 05-Jul-2007
Back to Top