Error: Critical Interrupt /PCIe Link, Bus uncorrectable error

If you are using any add-in RAID card, you may see the above error in your System Event Log (SEL), possibly accompanied by

System Firmware Error (POST Error). POST Code: A5A4

To resolve this issue, clear the SEL, then perform a CMOS Clear

CMOS Clear Procedure:

  1. Power down the server; do not remove AC power.
  2. Open the server and move the jumper from the default operating position (pins1-2) to the “clear” position (pins 2-3).
  3. Wait 5 seconds.
  4. Move the jumper back to the default position (pins 1-2).
  5. Close the server system and power up the server.
  6. CMOS is now cleared and can be reset by going into the BIOS setup.

This applies to:
Intel® Server Board S5000PAL

Solution ID: CS-030333
Date Created: 18-Mar-2009
Last Modified: 10-Aug-2011