LAN Manager* Workstation/Server v3.05
LAN Manager 2.2 Workstation/Server Installation Notes for Intel's
EtherExpress PRO/10 LAN Adapter
Location of Driver: \NDIS\MSLANMAN.BAT
MSLANMAN.BAT will create the following directory structure on local hard
drive:
\MSLANMAN.DOS\DRIVERS\ETHERNET\EPRO\EPRO.DOS (DOS NDIS driver)
\MSLANMAN.DOS\DRIVERS\ETHERNET\EPRO\PROTOCOL.INI
\MSLANMAN.DOS\DRIVERS\NIF\EPRODOS.NIF
\MSLANMAN.OS2\DRIVERS\ETHERNET\EPRO\EPRO.OS2 (OS/2 NDIS driver)
\MSLANMAN.OS2\DRIVERS\ETHERNET\EPRO\PROTOCOL.INI
\MSLANMAN.OS2\DRIVERS\NIF\EPROOS2.NIF
Sample Configuration Files
CONFIG.SYS (for DOS will contain):
DEVICE=C:\LANMAN\PROTMAN.DOS /I:C:\LANMAN
DEVICE=C:\LANMAN\EPRO.DOS
CONFIG.SYS (for OS/2* will contain):
DEVICE=C:\LANMAN\PROTMAN.OS2 /I:C:\LANMAN
DEVICE=C:\LANMAN\EPRO.OS2
General Installation
- Run the appropriate Microsoft* LAN Manager setup for the computer you
are setting up. (DOS, OS/2* or OS/2 Server). When prompted for the LAN
adapter driver, select Other Driver (the EtherExpress PRO/10 adapter
driver isn't included on the LAN Manager disk) and insert the disk you
created with the PRO/10 drivers, select the EtherExpress PRO/10 adapter
driver and follow the directions.
- When completed, reboot your computer for changes to take effect.
Hints and Tips
- Parameters for the PROTOCOL.INI file
Drivername: (required) If you have a single adapter, use the syntax in
the example below. If you are installing multiple adapters, each
adapter must have a unique driver name. Additional instances of the
driver would be referenced by DRIVERNAME=EPROx$, where "x" would be a
unique number 2 through 9.
IOAddress: (optional for single adapter systems - except when set to
certain addresses noted below) This value must match the adapter's I/O
address. If the driver does not find the adapter at the specified I/O
address, it will scan most of the I/O addresses that the adapter could
be at and will load if it finds the adapter. The only addresses the
driver doesn't scan are 2E0, 2F0 or 370. If you have used one of these
address, this parameter isn't optional. If you use multiple adapters in
one machine, make sure you specify the correct IOADDRESS for each board.
Otherwise, the driver will fail when loading on the second card.
Node: (optional) (Syntax: NODE="12 Hexadecimal digits") This value sets
the adapter's Individual Address, overriding the value read from the
adapter's EEprom. The value must be exactly 12 hexadecimal digits,
enclosed in double quotes. The value can't be all zeros, nor can it be
a multicast address.
If you want information on advanced PROTOCOL.INI parameters, refer to
the NDIS Driver Notes document or obtain document 6341 on Intel's
automated services.
- If you are having problems authenticating to a LAN Manager server,
use SoftSet2 to check if the PRO/10 is set to 8-bit mode. If it is, go
to Change Adapter Configuration, Advanced Options Menu and disable
Concurrent Processing.
- Sample PROTOCOL.INI for LAN Manager
[PROTMAN]
DRIVERNAME = PROTMAN$
DYNAMIC = YES
PRIORITY = NETBEUI
[NETBEUI_XIF]
Drivername = netbeui$
SESSIONS = 6
NCBS = 12
BINDINGS = EPRO_NIF
LANABASE = 0
[EPRO_NIF]
; PROTOCOL.INI section for the Intel® EtherExpress PRO/10
; Adapter
IOADDRESS = 0x300
DRIVERNAME = EPRO$
This applies to:
|