Products
|
 |
Intel® Server Chassis SR1400 |
 |
|
 |
 |
| A Flexible, 1U Rack-optimized Chassis for Performance-Intensive Solutions and High-Density Clusters |
 |
| Intel® Server Chassis SR1400 effectively blends performance, reliability and scalability with management, power, storage and cooling options designed specifically for rack-mount configurations in close quarters. |  |
Click to Enlarge |
|
|
|
 |
| Features |
Benefits |
| Specifically designed for and validated with the Intel® Server Board SE7520JR2 |
Performance advantages from an Intel® Xeon® processor-based server board; enhanced reliability and ease of integration.
 |
Support for up to three fixed SATA, hot-swap SATA, or hot-swap Ultra320 SCSI drives |
Storage flexibility, configurability for performance or price sensitivity. |
Tool-less assembly and installation of:
 | Cooling-fan replacement |
 | Standard control panel and Intel Local Control Panel1 |
 | PCI-X* risers |
 | PCI assembly and retention |
 | CD or floppy drive |
 | Hot-swap disk drives |
 | Rack slide rails |
 | Cable-management arm |
|
Simplified maintenance, lower service and support costs. |
| 500W power supply with two fans and Intel® Server Management monitoring interface |
Power headroom and monitoring ability for a fully equipped server. |
| Support for Intel® Local Control Panel |
Ability to monitor server operations and manage server directly from an optional server- attached control panel. |
|  |
|
|  |
| Form Factor |
1U Rack-Mount Server - SSI Thin E-Bay v3.1 -compatible. |
| Dimensions and Color |
 | Height 1.7", Width 16.93", Depth 26.46" (43 mm x 430 mm x 672 mm) |
 | Black (Intel Color Standard GE 701) |
|
| Hard-Drive-Bay Support |
| Fixed |
Up to three SATA or IDE |
| Hot-Swap |
Up to three SATA or SCSI |
| Peripheral Bay |
Tool-less slimline bay for a slimline CD, CD/DVD, or floppy drive; option to convert a hard-drive bay into a slimline floppy bay. |
| System Cooling |
Four dual-rotor 56mm fans and one single-rotor 28mm fan mounted in tool-less fan module and providing cooling for the processors, hard drives, and add-in cards; two 28mm fans for cooling the power supply; all fans monitored by Intel® Server Management and instrumented to provide RPM data for fan-failure prediction and detection. |
| Power Delivery |
| DC Power Supply |
500W PFC |
| AC Voltage |
100 127 / 200 240 V˜ 6.5 / 3.2A2 |
| +5V |
12A maximum |
| +5V Standby |
2A maximum |
| +12V |
35A maximum continuous |
| +3.3V |
16A maximum |
| -12V |
0.5A maximum |
| Control Panel |
| Buttons and Switches |
Power on/off (momentary) button, system reset button, ACPI sleep switch, tool-activated NMI switch. |
| LEDs |
Power, hard-drive activity, network activity (two), system ID (rack only), general system status, hot-swap and redundant-fan activity. |
| Connectors |
USB port, video (switched video with rear video connector). |
| Intel® Local Control Panel |
For monitoring and control of the server from the front panel. |
| Security |
Optional mechanical locking on the front bezel, an intrusion switch that can be monitored by Intel® Server Management. |
| Environment |
| Ambient Temperature |
Operating: +10°C to +35°C; non-operating: -40°C to +70°C |
| Relative Humidity |
Non-operating: 95% @ +30°C non-condensing |
| Acoustics |
5.7 bels actual |
| Electrostatic Discharge |
15kV air discharge, 8kV direct contact per Intel test specification. |
Safety and EMC Regulatory Compliance (Class A)
(EMC regulatory compliance is based on integration with a validated Intel server board and configuration as outlined in the Intel® Server Chassis SR1400 subassembly guide.). |
| Country and District |
Country and District Certification Safety and/or EMC |
Regulatory Marks Safety and/or EMC |
| Argentina |
IRAM |
Not applicable |
| Australia/New Zealand |
ACA, MED |
C-Tick |
| Belarus |
Bellis |
Not applicable |
| Canada |
UL / Industry Canada |
cULus / ICES |
| China |
CNCA |
CCC |
| Europe |
European Directives |
CE |
| Germany |
GS |
GS |
| International |
CB Report / CISPR |
Not Applicable |
| Japan |
VCCI |
VCCI |
| Korea |
RRL |
MIC |
| Russia |
GOST |
GOST |
| Taiwan |
BSMI RPC |
BSMI |
| United States |
UL / FCC |
CULus / FCC |
|  |
|
 |
1The Intel® Local Control Panel requires the purchase and installation of an optional Intel Management Module upgrade.
2The maximum amperage represents the value at which the chassis is rated.
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in intel's terms and conditions of sale for such products, intel assumes no liability whatsoever, and intel disclaims any express or implied warranty, relating to sale and/or use of intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice. Availability in different channels may vary.
|
|  | |
|