|
| The production SC5400LX KDK includes: |
|
|
|
| Redundant (1+0) 830W PFC power supply with dual line cord support (full redundancy requires additional 830W module purchased separately) |
|
| Four redundant hot swap fans and ducting |
|
| Support for up to 6 tool-free non hot-swap hard drives. Upgradeable to 10 hot-swap SAS or SATA. |
|
| Cables (one each): |
|
- Front Panel Cable (baseboard header to front panel)
- USB Cable (USB header to chassis front panel)
- Pre-routed IDE cable
- COM2 Cable
|
|
|
| Note: No AC power cords are included |
|
| The Intel® Server Chassis SC5400 is designed to work with boxed Intel processors that include a passive heat sink. |
|
|
| The production SC5400BRP KDK includes: |
|
|
|
| Redundant (1+0) 830W PFC power supply with dual line cord support (full redundancy requires additional 830W module purchased separately) |
|
| Two non-redundant cooling fans |
|
| Support for up to 6 tool-free non hot-swap hard drives. Upgradeable to 10 hot-swap SAS or SATA. |
|
| Cables (one each): |
|
- Front Panel Cable (baseboard header to front panel)
- USB Cable (USB header to chassis front panel)
- Pre-routed IDE cable
- COM2 Cable
|
|
|
| Note: No AC power cords are included |
|
| The Intel® Server Chassis SC5400 is designed to work with boxed Intel processors that include a passive heat sink. |
|
|
| Common accessories include: |
|
|
|
| Hot-Swap Drive Bays: |
|
- AXX6DRV3GEXP: Expander-based 6-drive bay that supports SAS/SATA drives. Requires two free SAS ports from the integrated SAS controller, ROMB Card or SAS RAID card.
- AXX4DRV3GEXP: Expander-based 4-drive bay that supports SAS/SATA drives. Requires two free SAS ports from the integrated SAS controller, ROMB Card or SAS RAID card. Only supported in SC5400 chassis family.
- AXX6DRV3G: 6-drive bay that supports SAS/SATA drives. Requires six free SAS or SATA ports.
SAS hard drive support requires SAS connectors from a SAS enabled board SKU, ROMB Card or SAS RAID Card.
- AXX4DRV3G: 4-drive bay that supports SAS/SATA drives. Requires four free SAS or SATA ports. SAS hard drive support requires SAS connectors from a SAS enabled board SKU, ROMB Card or SAS RAID Card. Only supported in SC5400 chassis family.
|
|
|
| FXX830WPSU: Additional 830W power supply module – required for full redundancy (for SC5400LX and SC5400BRP only) |
|
| ARIGRACK: Rack conversion kit (SC5400LX and SC5400 only) |
|
|
| Intel® Server Chassis SC5400 Order Codes |
| Intel® Building Block |
Description |
Quantity |
| SC5400BASE |
SC5400 Base Chassis w/670W PFC Fixed PSU, 2 chassis fans, 1 PSU fan, supports up to 6 tool-free cabled drives, upgradeable to 6 hot-swap drives (SAS or SATA), without power cord |
1 |
| SC5400BASENA |
Same as SC5400BASE with North American power cord included. |
1 |
| SC5400BRP |
SC5400 Base Redundant Power (BRP) Chassis w/830W PFC redundant PSU (2nd PSU module is required for redundancy), 2 chassis fans, 1 PSU fan, supports up to 6 tool-free cabled drives, upgradeable to 10 hot-swap SAS or SATA drives, without power cord |
1 |
| SC5400BRPNA |
Same as SC5400BRP with North American power cord included. |
1 |
| SC5400LX |
SC5400LX Chassis w/830W PFC redundant PSU (2nd PSU module is required for redundancy), 4 hot-swap redundant fans, 1 PSU fan per module, supports up to 6 tool-free cabled drives, upgradeable to 10 hot-swap SAS or SATA drives, without power cord |
1 |
| SC5400LXNA |
Same as SC5400LX with North American power cord included. |
1 |
|