Products
Intel® Server Chassis SC5300
overview product support
Maximum Reliability, Scalability and Manageability in a Highly Versatile Chassis
The Intel® Server Chassis SC5300 combines outstanding reliability, extensive scalability, and superior manageability in a versatile chassis designed to meet diverse needs. This chassis provides an ideal foundation for a range of environments, from multi-purpose servers for small businesses to workgroup database servers and departmental Exchange* servers. Configurable in a pedestal or rack-mount form factor, the Intel Server Chassis SC5300 includes an assortment of options to effectively handle current and future storage and performance requirements.Intel® Server Chassis SC5300
Click to Enlarge
Download Product Brief (PDF 2.8MB)
View Intel® Virtual System Tour
View Recommended Configurations and Order Codes
Ad Builder
Intel® Server Chassis SC5300 Features
Features Benefits
Specifically designed for and validated with Intel® Server Board SE7520BD2 Scalable performance advantages from Intel® Xeon® processor-based server boards: enhanced reliability and ease of integration.
Available in pedestal and 5U rack-mount configurations Reconfigurable for diverse applications and settings.
Support for up to 6 fixed or hot-swap drives3 in the SC5300BASE chassis and 10 in the following SC5300BRP and SC5300LX chassis configurations:
Four- and six-drive fixed hard-disk drive bays
Six-drive hot-swap SATA drive bay
Four- and six-drive hot-swap SCSI drive bays (See all configuration options.)
Up to 3 terabytes of storage capacity to handle current and future storage needs. Configuration flexibility to meet diverse server and application environments.
Intel® Power and Thermal Headroom:
600W fixed power supply (SC5300BASE configuration)
730W PFC 1+1 redundant power supply2 (SC5300BRP and SC5300LX configurations)
Two high-flow system fans and one power-supply fan per power supply (SC5300BASE and SC5300BRP configurations)
Four high-flow redundant system fans1 and one power supply fan (per supply in SC5300LX configurations)
Support for add-in cards and peripherals
(Note that full cooling redundancy requires the purchase and installation of an optional Intel® Management Module upgrade; see the complete product specifications for details.)
Power sufficient to meet current and future application needs.
Protection against heat-related performance degradation or thermal-related system failure.
System expandability.
Support for Intel® Local Control Panel3 Ability to monitor server operations and manage server directly from an optional server-attached control panel.
Tool-less assembly and installation of fixed and hot-swap drive bays, fixed drives in fixed-drive bay, 5.25 inch bay peripherals, hot-swap fans, side-access cover, hot-swap power supply Simplified maintenance for lower service and support costs.
Related Products
Processors Intel® Xeon® Processor
Server Boards
RAID Controllers
Other
Intel® Server Management
Intel® PRO Server Adapters
Intel® Server Chassis SC5300 Specifications
Form Factor Pedestal or 5U Rack-Mount Server Server Standards Infrastructure (SSI) Entry E-Bay 3.5 compatible.
Dimensions and Color
Pedestal 16.9" (height) x 8.6" (width) x 27.9" (depth) (429 mm x 218 mm x 709 mm) Black (Intel Color Standard GE 701).
Rack-Mount Server 5U 8.6" (height) x 16.7" (width) x 27.4" (depth) (218 mm x 424 mm x 696 mm) Black (Intel Color Standard GE 701).
Hard-Drive-Bay Support SC5300BASE SC5300BRP SC5300LX
Shipping Configuration Up to six3 fixed SATA, Ultra320 SCSI4, or IDE (one-inch height). Up to six fixed SATA, Ultra320 SCSI4, or IDE (one-inch height). Up to six fixed SATA, Ultra320 SCSI4, or IDE (one-inch height).
Hot-Swap Drive Bay Upgrade Support Upgradable to support six SATA or Ultra320 SCSI (one-inch height) hot-swap hard drives3. Upgradable to support an additional 4 fixed hard drives or a combination of a 6-drive SATA drive bay, a 6-drive hot-swap Ultra320 SCSI drive bay, and a 4-drive hot-swap Ultra320 SCSI drive bay for a total of 10 fixed or hot-swap hard drives (hot-swap drive bays support one-inch hot-swap hard drives)3. Upgradable to support an additional 4 fixed hard drives or a combination of a 6-drive SATA drive bay, a 6-drive hot-swap Ultra320 SCSI drive bay, and a 4-drive hot-swap Ultra320 SCSI drive bay for a total of 10 fixed or hot-swap hard drives (hot-swap drive bays support one-inch hot-swap hard drives)3.
SCSI Backplane LVD with SAF-TE LVD with SAF-TE LVD with SAF-TE
External Peripheral Bays Up to 3 at 5.25" (1.75" height) Up to 3 at 5.25" (1.75" height) Up to 3 at 5.25" (1.75" height)
System Cooling
SC5300BASE5 One 120mm and one 92mm fan positioned for main chassis cooling that can be monitored by Intel® Server Management7; both system fans instrumented to provide RPM data for fan-failure prediction and detection; one 80mm fan for power-supply cooling.
SC5300BRP5 One 120mm and one 92mm fan positioned for main chassis cooling that can be monitored by Intel® Server Management7; both system fans instrumented to provide RPM data for fan-failure prediction and detection; one 80mm fan per power supply module for power-supply cooling.
SC5300LX5 Two 120mm and two 92mm hot-swap redundant3 fans providing cooling for the processors, hard drives, and add-in cards that can be monitored by Intel® Server Management7 for fail-over capability; all system fans instrumented to provide RPM data for fan-failure prediction and detection; one 80mm fan per power supply module for power-supply cooling.
Power Delivery SC5300BASE SC5300BRP SC5300LX
DC Power Supply 600W PFC 730W PFC, dual-line cord 1+1 redundant-power-capable4. 730W PFC, dual-line cord 1+1 redundant-power-capable4.
AC Voltage 100 127 / 200 240 V~; 6.0 / 3A9 100 127 / 200-240 V~; 6 / 3A9 100 127 / 200-240 V~; 6 / 3A9
+5V 24A maximum 24A maximum4 24A maximum
+5V Standby 2A maximum 2A maximum 2A maximum
+12V 43A maximum sustained 48A maximum sustained 48A maximum sustained
+3.3V 20A maximum 24A maximum 24A maximum
-12V 0.5A maximum 0.5A maximum 0.5A maximum
Front Panel
Buttons and Switches Power on/off (momentary) button, system-reset button, ACPI sleep6 switch, tool-activated NMI switch.
LEDs Power, hard-drive activity, network activity (two), system ID, general system status.
Connectors Two USB ports, one serial port.
Intel® Local Control Panel (optional) For monitoring.
Security A mechanical lock on the front bezel that when locked prevents access via the side panel and front bezel, removable padlock loop to prevent removal of the system-access cover (for rack security), and a lock hole at rear of chassis, two intrusion switches that can be monitored by Intel® Server Management.
Environment
Ambient Temperature Operating: +10°C to +35°C; non-operating: 40°C to +70°C.
Relative Humidity Non-operating: 95% @ +30°C non-condensing.
Electrostatic Discharge 15kV per Intel test specification.
Safety and EMC Regulatory Compliance (Class A) (EMC regulatory compliance is based on integration with a validated Intel® Server Board and configuration as outlined in the Intel® Server Chassis SC5300 subassembly guide.)
Country and District Certification
Safety and/or EMC
Regulatory Marks
Safety and/or EMC
Argentina IRAM Not Applicable
Australia/New Zealand ACA, MED C-Tick
Belarus Bellis Not Applicable
Canada UL / Industry Canada cULus / ICES
China CNCA CCC
Europe European Directives CE
Germany GS GS
International CB Report / CISPR Not Applicable
Japan VCCI VCCI
Korea RRL MIC
Russia GOST GOST
Taiwan BSMI RPC BSMI
Ukraine Ukraine Not Applicable
United States UL / FCC CULus / FCC
Back to Top