Products
|
 |
Intel® Server Chassis SC5300 |
 |
|
 |
 |
| Maximum Reliability, Scalability and Manageability in a Highly Versatile Chassis |
 |
| The Intel® Server Chassis SC5300 combines outstanding reliability, extensive scalability, and superior manageability in a versatile chassis designed to meet diverse needs. This chassis provides an ideal foundation for a range of environments, from multi-purpose servers for small businesses to workgroup database servers and departmental Exchange* servers. Configurable in a pedestal or rack-mount form factor, the Intel Server Chassis SC5300 includes an assortment of options to effectively handle current and future storage and performance requirements. |  |
Click to Enlarge |
|
|
|
 |
| Features |
Benefits |
| Specifically designed for and validated with Intel® Server Board SE7520BD2 |
Scalable performance advantages from Intel® Xeon® processor-based server boards: enhanced reliability and ease of integration. |
| Available in pedestal and 5U rack-mount configurations |
Reconfigurable for diverse applications and settings. |
Support for up to 6 fixed or hot-swap drives3 in the SC5300BASE chassis and 10 in the following SC5300BRP and SC5300LX chassis configurations:
 | Four- and six-drive fixed hard-disk drive bays |
 | Six-drive hot-swap SATA drive bay |
 | Four- and six-drive hot-swap SCSI drive bays (See all configuration options.) |
|
Up to 3 terabytes of storage capacity to handle current and future storage needs. Configuration flexibility to meet diverse server and application environments. |
Intel® Power and Thermal Headroom:
 | 600W fixed power supply (SC5300BASE configuration) |
 | 730W PFC 1+1 redundant power supply2 (SC5300BRP and SC5300LX configurations) |
 | Two high-flow system fans and one power-supply fan per power supply (SC5300BASE and SC5300BRP configurations) |
 | Four high-flow redundant system fans1 and one power supply fan (per supply in SC5300LX configurations) |
 | Support for add-in cards and peripherals |
(Note that full cooling redundancy requires the purchase and installation of an optional Intel® Management Module upgrade; see the complete product specifications for details.) |
 | Power sufficient to meet current and future application needs. |
 | Protection against heat-related performance degradation or thermal-related system failure. |
 | System expandability. |
|
| Support for Intel® Local Control Panel3 |
Ability to monitor server operations and manage server directly from an optional server-attached control panel. |
| Tool-less assembly and installation of fixed and hot-swap drive bays, fixed drives in fixed-drive bay, 5.25 inch bay peripherals, hot-swap fans, side-access cover, hot-swap power supply |
Simplified maintenance for lower service and support costs. |
|  |
|
|  |
| Form Factor |
Pedestal or 5U Rack-Mount Server Server Standards Infrastructure (SSI) Entry E-Bay 3.5 compatible. |
| Dimensions and Color |
| Pedestal |
16.9" (height) x 8.6" (width) x 27.9" (depth) (429 mm x 218 mm x 709 mm) Black (Intel Color Standard GE 701). |
| Rack-Mount Server |
5U 8.6" (height) x 16.7" (width) x 27.4" (depth) (218 mm x 424 mm x 696 mm) Black (Intel Color Standard GE 701). |
| Hard-Drive-Bay Support |
SC5300BASE |
SC5300BRP |
SC5300LX |
| Shipping Configuration |
Up to six3 fixed SATA, Ultra320 SCSI4, or IDE (one-inch height). |
Up to six fixed SATA, Ultra320 SCSI4, or IDE (one-inch height). |
Up to six fixed SATA, Ultra320 SCSI4, or IDE (one-inch height). |
| Hot-Swap Drive Bay Upgrade Support |
Upgradable to support six SATA or Ultra320 SCSI (one-inch height) hot-swap hard drives3. |
Upgradable to support an additional 4 fixed hard drives or a combination of a 6-drive SATA drive bay, a 6-drive hot-swap Ultra320 SCSI drive bay, and a 4-drive hot-swap Ultra320 SCSI drive bay for a total of 10 fixed or hot-swap hard drives (hot-swap drive bays support one-inch hot-swap hard drives)3. |
Upgradable to support an additional 4 fixed hard drives or a combination of a 6-drive SATA drive bay, a 6-drive hot-swap Ultra320 SCSI drive bay, and a 4-drive hot-swap Ultra320 SCSI drive bay for a total of 10 fixed or hot-swap hard drives (hot-swap drive bays support one-inch hot-swap hard drives)3. |
| SCSI Backplane |
LVD with SAF-TE |
LVD with SAF-TE |
LVD with SAF-TE |
| External Peripheral Bays |
Up to 3 at 5.25" (1.75" height) |
Up to 3 at 5.25" (1.75" height) |
Up to 3 at 5.25" (1.75" height) |
| System Cooling |
| SC5300BASE5 |
One 120mm and one 92mm fan positioned for main chassis cooling that can be monitored by Intel® Server Management7; both system fans instrumented to provide RPM data for fan-failure prediction and detection; one 80mm fan for power-supply cooling. |
| SC5300BRP5 |
One 120mm and one 92mm fan positioned for main chassis cooling that can be monitored by Intel® Server Management7; both system fans instrumented to provide RPM data for fan-failure prediction and detection; one 80mm fan per power supply module for power-supply cooling. |
| SC5300LX5 |
Two 120mm and two 92mm hot-swap redundant3 fans providing cooling for the processors, hard drives, and add-in cards that can be monitored by Intel® Server Management7 for fail-over capability; all system fans instrumented to provide RPM data for fan-failure prediction and detection; one 80mm fan per power supply module for power-supply cooling. |
| Power Delivery |
SC5300BASE |
SC5300BRP |
SC5300LX |
| DC Power Supply |
600W PFC |
730W PFC, dual-line cord 1+1 redundant-power-capable4. |
730W PFC, dual-line cord 1+1 redundant-power-capable4. |
| AC Voltage |
100 127 / 200 240 V~; 6.0 / 3A9 |
100 127 / 200-240 V~; 6 / 3A9 |
100 127 / 200-240 V~; 6 / 3A9 |
| +5V |
24A maximum |
24A maximum4 |
24A maximum |
| +5V Standby |
2A maximum |
2A maximum |
2A maximum |
| +12V |
43A maximum sustained |
48A maximum sustained |
48A maximum sustained |
| +3.3V |
20A maximum |
24A maximum |
24A maximum |
| -12V |
0.5A maximum |
0.5A maximum |
0.5A maximum |
| Front Panel |
| Buttons and Switches |
Power on/off (momentary) button, system-reset button, ACPI sleep6 switch, tool-activated NMI switch. |
| LEDs |
Power, hard-drive activity, network activity (two), system ID, general system status. |
| Connectors |
Two USB ports, one serial port. |
| Intel® Local Control Panel (optional) |
For monitoring. |
| Security |
A mechanical lock on the front bezel that when locked prevents access via the side panel and front bezel, removable padlock loop to prevent removal of the system-access cover (for rack security), and a lock hole at rear of chassis, two intrusion switches that can be monitored by Intel® Server Management. |
| Environment |
| Ambient Temperature |
Operating: +10°C to +35°C; non-operating: 40°C to +70°C. |
| Relative Humidity |
Non-operating: 95% @ +30°C non-condensing. |
| Electrostatic Discharge |
15kV per Intel test specification. |
| Safety and EMC Regulatory Compliance (Class A) |
(EMC regulatory compliance is based on integration with a validated Intel® Server Board and configuration as outlined in the Intel® Server Chassis SC5300 subassembly guide.) |
| Country and District |
Certification Safety and/or EMC |
Regulatory Marks Safety and/or EMC |
| Argentina |
IRAM |
Not Applicable |
| Australia/New Zealand |
ACA, MED |
C-Tick |
| Belarus |
Bellis |
Not Applicable |
| Canada |
UL / Industry Canada |
cULus / ICES |
| China |
CNCA |
CCC |
| Europe |
European Directives |
CE |
| Germany |
GS |
GS |
| International |
CB Report / CISPR |
Not Applicable |
| Japan |
VCCI |
VCCI |
| Korea |
RRL |
MIC |
| Russia |
GOST |
GOST |
| Taiwan |
BSMI RPC |
BSMI |
| Ukraine |
Ukraine |
Not Applicable |
| United States |
UL / FCC |
CULus / FCC |
|  |
|
 | 1 The SC5300BASE configuration includes a 600W fixed power supply. The SC5300BRP and SC5300LX configurations include a 730W 1+1 redundant power supply. Full redundancy requires the purchase of an optional second power supply, order code FXX730WPSU.
2 These boards only support SC5300BASE.
3 Full redundancy requires the purchase of an optional second power supply, order code FXX730WPSU.
4 Full cooling redundancy requires the purchase and installation of an optional Intel® Management Module upgrade.
5 The Intel® Local Control Panel requires the purchase and installation of an optional Intel® Management Module upgrade.
6 The Ultra320 SCSI drive bays are compatible with Ultra2 SCSI.
7 Full redundancy requires the purchase and installation of an optional Intel® Management Module upgrade.
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's terms and conditions of sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right.
Intel products are not intended for use in medical, life saving, life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice. Availability in different channels may vary.
|
|  | |
|