Products
Home ›  Products ›  Enterprise Blade Servers ›
Intel® Optical Pass-thru Module SBCEOPM
OverviewSupportWhere to buy
 
Enhance Server Connectivity with Intel® Optical Pass-Thru Modules
Easily integrate a blade server into your existing data center network environment with the use of the Intel® Server Blade Chassis (SBCE) paired with Optical Pass-thru Modules (SBCEOPM). This combination offers enhanced flexibility to connect to existing external Fibre Channel SAN switch or Fiber-optic Gigabit Ethernet switch infrastructure, as well as external direct-attach Fibre Channel storage devices, while maintaining maximum I/O performance with one-to-one connections.
 
Download Product Brief (PDF 189KB)
 
Key Features of the Intel® Optical Pass-thru Module
Features
14 internal ports to connect to Intel® Server Compute Blades
14 external network interface ports via 4 Optical Pass-thru SC or LC cables
Fits into any of the chassis' four network bays
Compatibility and interoperability support for heterogeneous network environments
Auto-sensing to support Fibre Channel SAN or Fiber-optic Gigabit Ethernet LAN switches
No configuration is required
 
Related Products
Processors Intel® Xeon® Processor
Blade Server Chassis Intel® Blade Server Chassis SBCE
Server Compute Blades Intel® Server Compute Blade SBXD132
Intel® Server Compute Blade SBX82
Networking and Storage Connectivity Intel® Blade Server Ethernet Solution
Intel® Blade Server Fibre Channel Solution
 
Intel® Optical Pass-thru Module Product Specifications
Module
Pass-Thru Ports
Number of Ports 14 internal ports to connect to blade servers, 4 external bi-directional interface ports to connect to Optical Pass-thru Module cable.
External Port Type Each port on the Optical Pass-thru Module supports four channel pairs of optical connectors to connect to your existing 2-Gbit/sec FC SAN or 1 GbE-LX/SX network infrastructure. Auto sensing between network interfaces.
Internal Port Type 2-Gbit/sec FC SAN (or) 1 GbE Ports
Port Characteristics
External ports are automatically detected and self configuring
Cables
Pass-thru Module Cables
Network Cables Optical SC Cable
Optical LC Cable
Pass-Thru Module
Switch Maintainability
Diagnosis Power-on self-test (POST) is performed on all functional components. Port operational tests include internal, external, and online tests.
User Interface LED indicators
Dimensions
Width 29 mm (1.14 in.)
Height A112 mm (4.41 in.)
Depth 260.3 mm (10.25 in.)
Weight .91 kg. (2 lb)
Environmental
Temperature and Altitude Operating: 10°C to 35°C (50°F to 95°F) at an altitude of 0 to 914m (0 to 3,000 ft.), 10°C to 32°C (50°F to 89.6°F) at an altitude of 914 to 3000m (0 to 10,000 ft.)
Humidity Operating: 8% to 80%, non-condensing
Electrical
Heat output: 85.3 Btu (25 watts)
Operating voltage: 12V dc
Circuit protection: Internally fused with over-current
Safety Compliance
USA: UL 60950 - 3rd Edition/CSA 22.2. No. 60950
Canada: cUL certified - 3rd Edition/CSA 22.2. No. 60950- for Canada (product bears the single cUL mark for U.S. and Canada)
Europe: Low Voltage Directive, 73/23/EEC TUV/CB to EN60950 3rd Edition TUV/CB - EMKO-TSE (74-SEC) 207/94
International: CB Report to IEC 60950 3rd Edition with all International Deviations
Australia/New Zealand: CB Report to IEC 60950, 3rd Edition plus international Australia/New Zealand deviations
Electromagnetic Compatibility (EMC)
USA: FCC Part 15, Class A
Canada: ICES-003 issue 3
Europe: EN55022:1998, Class A, ITE Specific Radiated and Conducted Emissions CE Mark
Japan: VCCI/3/99.05 Class A
Australia/New Zealand: AS/NZS 3548, Class A Limit
Korea: RRL Approval
Russia: Gost Approval
Other International: CISPR 22:1997
Intel® Optical Pass-Thru Module SC Cable (SBCEOPMSC)
Connects Optical Pass-thru Module Pass-thru Module with the external network
Description Eight industry-standard duplex LC fiber-optic cable connections that support four bi-directional optical channels.
Couplers The kit comes with optical couplers that enable the cables to be extended up to 1000 meters.