The browser version you are using is not recommended for this site.
Please consider upgrading to the latest version of your browser by clicking one of the following links.

Support

TA-1013: Firmware Update to Resolve AC Power Cycling Cache Backup Issue


Last Reviewed: 17-Aug-2016
Article ID: 000020098

TA-1013: Firmware Update to Resolve AC Power Cycling Cache Backup Issue (PDF) icon
This document describes the root cause and corrective action found during AC cycle testing. The cache memory can be lost even through cache protection is enabled. The issue is rare, and can be fixed by upgrading your Intel® RAID Controller.

 

Size: 135 KB
Date: July 2012

Note: PDF files require Adobe Acrobat Reader*.

This article applies to: